Belden

0935 253 122 - CANopen / DeviceNet Data Single-Ended Cordset: M12 Standard, female, straight, 5-pin, A-coded, black body, 50 V AC / 60 V DC, 4 A; PUR black cable, 4-wires, Data: 2x0.25 mm² + Power: 2x0.34 mm²

(No reviews yet) Write a Review
SKU:
0935 253 122
Shipping:
Calculated at Checkout
$0.00

Description

CANopen / DeviceNet Data Single-Ended Cordset: M12 Standard, female, straight, 5-pin, A-coded, black body, 50 V AC / 60 V DC, 4 A; PUR black cable, 4-wires, Data: 2x0.25 mm² + Power: 2x0.34 mm²

Specifications

Specifications

Face View

Pin 1Pin 2Pin 3Pin 4Pin 5
shieldredblackwhiteblue
Product FamilyData Connectors
Product Sub FamilyM12 Standard
Connector TypeCordset, single ended
Type of Contact / GenderFemale
Connector DesignStraight
Number of Pins5
CodingA
ShieldingUnshielded
Attachment TypeCoupling Nut
Rated Voltage60 V
Rated Impulse Voltage1.5 kV
Operating Voltage50 V AC / 60 V DC
Rated Current*4 A
Data TransmissionCANopen / DeviceNet
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*- 40 °C - + 80 °C
Protection Degree / IP Rating**IP65, IP67, IP68 (1 m / 24 h), IP69K
Design StandardIEC 61076-2-101
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuSn
Contact PlatingCu/Au
Contact Bearer MaterialTPU
Contact Bearer ColorBlack
Flammability Class (Contact Bearer)UL 94 HB
Molded Body MaterialTPU
Molded Body ColorBlack
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialStainless Steel

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number253
Conductor SizeData: 2x0.25 mm² + Power: 2x0.34 mm²
Number of Wires4
Minimal Bending Radius (Fixed Inst)˃ 5 x D
Minimal Bending Radius (Flexible Inst)˃ 10 x D
Cycles (Bending)˃ 1 M
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colorblack matt similarly RAL 9005
Cable Diameter Dø 6.70 ± 0.20 mm
Wire Insulation MaterialData: PE + Power: PE or PP
Insulated Wire DiameterData: ø 2.05 ± 0.10 mm + Power: ø 1.40 ± 0.05 mm
Overall Shield (Cable)Cu-ETP1 tinned
Element ShieldAl-PT Foil
Foil shieldAl-PT Foil
Ambient Temperature (Fixed Installation)- 50 °C - + 80 °C
Ambient Temperature (Flex Installation)- 25 °C - + 80 °C
Ambient Temperature (Drag Chain Inst)- 25 °C - + 60 °C
UL Cable TypeAWM: 20549 or 21198
Flammability Class (Cable Jacket)DIN EN 60332-1-2, VDE 0482-332-1-2, IEC 60332-1-2, UL VW-1, CSA FT-1
Cable CharacteristicsExclusion of dangerous materials; Line construction acc. CAN-Bus and DeviceNET specification; Good microbes and hydrolysis resistance; Mainly plasticizer diffusion free; Good chemical and oil resistance; Exclusion of PVC and Silicone; Free of lacquer wetting disturbing substances; Coldness flexibility
Core ColorsData: blue, white + Power: red, black

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

HalogenfreeDIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1

Notes

Note DeratingNotice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
NoteDo not connect or disconnect under load.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 6869:
6869|0935 253 122/0,6 M|0.6 m
Variant_Options 7296:
7296|0935 253 122/2 M|2 m
Variant_Options 16051:
16051|0935 253 122/15 M|15 m
Variant_Options 16052:
16052|0935 253 122/25 M|25 m
View AllClose