LioN-P, IO-Link I/O Hub, IO-Link, industrial metal housing, 60 mm, up to IP69K, 16 digital input channels, 8 x M12 A-coded I/O connection, 5-poles, 1x M12 A-coded IO-Link Class A connection, 5-poles
Specifications
Specifications
| Product Family | I/O Systems: Active - Standalone |
|---|
| Product Sub Family | LioN-P |
|---|
| Item Description | 0960 IOL 381-001 |
|---|
| Device Type | IO-Link Hub |
|---|
| Protocol | IO-Link |
|---|
| I/O Function | 16DI |
|---|
| Bus Connection | M12, 5-poles, A-coded |
|---|
| Power Connection (System Supply) | M12, 5-poles, A-coded |
|---|
| Replacement for | 934992001 |
|---|
| I/O Connection | M12, 5-poles, A-coded |
|---|
| I/O Type | Digital Input |
|---|
General Data
| Housing Material | Metal, Zinc Die-cast |
|---|
| Housing Plating | Nickel, matt |
|---|
| Housing Color | Grey Metallic |
|---|
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
|---|
| Potted | Yes |
|---|
| Dimensions (W x H x D) | 60 mm x 31 mm x 159 mm |
|---|
| Weight | 390 g |
|---|
| Ambient Temperature (Operation)* | -20 °C to 70 °C |
|---|
| Ambient Temperature (Storage/Transport) | -25 °C to 85 °C |
|---|
| Permissible Humidity (Operation) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Permissible Humidity (Storage/Transport) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Air Pressure (Operation) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Air Pressure (Storage/Transport) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Flammabilty Class | UL 94 (IEC 61010) |
|---|
| Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
|---|
| Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
|---|
| Vibration Resistance | 15 g / 5 -500 Hz |
|---|
| Shock Resistance | 50 g / 11ms |
|---|
| Mean Time To Failure (MTTF) | 2111 years. acc. to Telcordia SR-332 (2011) 20°C |
|---|
| Contact Base Material | M12, A-coded, CuSn, Gold-plated |
|---|
| Contact Bearer Material | PA |
|---|
| O-Ring Material | FKM |
|---|
| Mounting | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
|---|
| Fastening Torque (Fixing Screw) | M4: 1 Nm |
|---|
| Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
|---|
| Fastening Torque (Bus Connection) | M12: 0.5 Nm |
|---|
| Fastening Torque (Power Connection) | M12: 0.5 Nm |
|---|
| Fastening Torque (I/O Connection) | M12: 0.5 Nm |
|---|
Modbus TCP
| Connection | M12, 5-poles, A-coded |
|---|
IO-Links
| Protocol | IO-Link |
|---|
| IO-Link Class | Class A |
|---|
| Number of Connections | 1 |
|---|
| Specification | V1.1.2 |
|---|
| Transmission Rate / COM Mode | COM 3 (230.4 kbps) |
|---|
| Cycle Time / Update Rate | min. 1 ms |
|---|
| Parameter Storage | Supported |
|---|
| Frame Type | Type_2_V |
|---|
| Process Data Length | 4 Bytes Input Data, 4 Bytes Output Data |
|---|
| Configuration | IODD, Process Data |
|---|
Power Supply
| Connection Module Supply Voltage | M12, 5-poles, A-coded |
|---|
| Number of Connections | 1 |
|---|
| Current Carrying Capacity of Connector | max. 4 A |
|---|
| Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Module Supply Voltage (Range) | 18 V DC to 30 V DC |
|---|
| Current Consumption (typ.) | 80 mA (at 24 V DC) |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (System Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
| Connection Sensor Supply Voltage | via Module Supply Connection |
|---|
| Current Carrying Capacity of Connector | max. 4 A |
|---|
| Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Sensor Supply Voltage (Range) | 18 V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (Sensor Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
Digital Input Channels
| Number of Digital Input Channels | max. 16, fixed |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| Number of Ports | 8x, X1 to X8 |
|---|
| Channel Type | Type 1 acc. to IEC 61131-2 |
|---|
| Sensor Current Supply | max. 700 mA per module (Consider 1L+ limitation of connected IO-Link Master) |
|---|
| Input Wiring | 2-, 3-wire |
|---|
| Nominal Voltage | 24 V DC via US (module power supply) |
|---|
| Nominal Current | typ. 5 mA |
|---|
| Sensor Type | PNP |
|---|
| Input Voltage Range "0" signal | -0,3V DC ... 5 V DC |
|---|
| Input Voltage Range "1" signal | 15 V DC ... 30 V DC |
|---|
| Input Filter Time | 0 to 3 ms, configurable |
|---|
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
|---|
| Status Indicator (Inputs) | LED white or yellow per channel |
|---|
Electrical Isolation
| US (System Supply Voltage) / FE | 500 V DC |
|---|
| Bus connection / FE | 500 V DC |
|---|
EMC Conformance
| EMC Directive | 2014/30/EU |
|---|
| EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
|---|
| EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
|---|
| EN 61000-4-4 Fast Transients (Burst) | Criterion B, 2 kV |
|---|
| EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
|---|
| EN 61000-4-6 Conducted immunity | Criterion A; Test voltage 10 V |
|---|
| EN 55022 Radio Interference Properties | Class A |
|---|
Safety & Environmental Compliance
| CE | Yes |
|---|
| RoHS Compliant | Yes |
|---|
| China RoHS-Compliant | Yes |
|---|
Approvals
| UL | cULus Listed, UL 61010-1 |
|---|
| UL-File | E230848 |
|---|
| CSA | Yes, via UL |
|---|
| IO-Link | Yes |
|---|
Notes
| Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |
|---|
| Update and Revision | Revision Number: 0.88 Revision Date: 11-14-2022 |
|---|
Documentation
Product Bulletins
Blogs
Reference Manuals
Software
Safety Guidance
Technical Information
Product Certifications
Data Sheets