LioN-P, IO-Link Master, Multiprotocol (PROFINET and EtherNet/IP), industrial metal housing, 30 mm, up to IP69K, 4 digital input and 8 IO-Link Master, 8 x M8 B-coded I/O connection, 5-poles, 2 x M12 D-coded bus connection, 4-poles, 2 x M12 L-coded power supply connection, 5-poles
Specifications
Specifications
Product Family | I/O Systems: Active - Standalone |
---|
Product Sub Family | LioN-P |
---|
Item Description | 0980 ESL 199-122 |
---|
Device Type | IO-Link Master |
---|
Protocol | Multiprotocol, PROFINET, EtherNet/IP |
---|
I/O Function | 4DI 8IOL |
---|
Bus Connection | M12, 4-poles, D-coded |
---|
Power Connection (System Supply) | M12 Power, 5-poles, L-coded |
---|
I/O Connection | M8, 5-poles, B-coded |
---|
I/O Type | Digital Input/ Digital Output/IO-Link |
---|
General Data
Housing Material | Metal, Zinc Die-cast |
---|
Housing Plating | Nickel, matt |
---|
Housing Color | Grey Metallic |
---|
Protection Degree / IP Rating** | IP65, IP67, IP69K |
---|
Potted | Yes |
---|
Dimensions (W x H x D) | 30 mm x 43 mm x 204 mm |
---|
Weight | 450 g |
---|
Ambient Temperature (Operation)* | -20 °C to 70 °C |
---|
Ambient Temperature (Storage/Transport) | -25 °C to 85 °C |
---|
Permissible Humidity (Operation) | 5 % ... 95 % (For UL applications max. 80 %) |
---|
Permissible Humidity (Storage/Transport) | 5 % ... 95 % (For UL applications max. 80 %) |
---|
Air Pressure (Operation) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
---|
Air Pressure (Storage/Transport) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
---|
Flammabilty Class | UL 94 (IEC 61010) |
---|
Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
---|
Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
---|
Vibration Resistance | 15 g / 5 -500 Hz |
---|
Shock Resistance | 50 g / 11ms |
---|
Mean Time To Failure (MTTF) | 616 years. acc. to Telcordia SR-332 (2011) 20°C |
---|
Contact Base Material | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
---|
Contact Bearer Material | PA |
---|
O-Ring Material | FKM |
---|
Mounting | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
---|
Fastening Torque (Fixing Screw) | M4: 1 Nm |
---|
Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
---|
Fastening Torque (Bus Connection) | M12: 0.5 Nm |
---|
Fastening Torque (Power Connection) | M12: 0.5 Nm |
---|
Fastening Torque (I/O Connection) | M8: 0.3 Nm |
---|
Included in Delivery | Attachable Labels: 15x, Sealing Caps: 5x M12 |
---|
PROFINET
Protocol | PROFINET |
---|
Connection | M12 LAN, 4-poles, D-coded |
---|
Number of Connections | 2 |
---|
Specification | V2.3X |
---|
Conformance Class | C |
---|
Performance Class | RT (switch supports IRT) |
---|
Netload Class | II |
---|
Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
---|
Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
---|
Cycle Time / Update Rate | min. 1 ms |
---|
Addressing | DCP |
---|
Fast Startup (FSU) | Supported, ≤ 2000 ms |
---|
Media Redundancy Protocol (MRP) | Supported, MRP client |
---|
Shared Device | Supported |
---|
Topology Detection | LLDP, SNMP V1 |
---|
Easy Device Replacement | Supported, based on LLDP |
---|
Supported Network Protocols (Other) | ARP, HTTP, Ping, SNMP V1, TCP/IP |
---|
EtherNet/IP
Protocol (EtherNet/IP) | EtherNet/IP |
---|
Connection | M12 LAN, 4-poles, D-coded |
---|
Number of Connections | 2 |
---|
Specification | CIP V3.1x, EIP Adaption of CIP V1.1x |
---|
Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
---|
Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
---|
Cycle Time / Requested Packet Interval (RPI) | min. 1 ms |
---|
Addressing | BootP, DHCP, Rotary Address Switches |
---|
Address Switches Range | 0 to 255 dec |
---|
Connection Types | Exclusive Owner, Input Only, Listen Only |
---|
CIP Msg Connection Limit | 6 |
---|
CIP I/O Connection Limit | 3 |
---|
Device Level Ring (DLR) | Supported, beacon based |
---|
Quick Connect (QC) | Not supported |
---|
Supported Network Protocols (Other) | ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP |
---|
Power Supply
Connection Module Supply Voltage | M12 Power, 5-poles, L-coded |
---|
Number of Connections | 2 |
---|
Current Carrying Capacity of Connector | max. 16 A |
---|
Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
---|
Module Supply Voltage (Range) | 18 V DC to 30 V DC |
---|
Current Consumption (typ.) | 180 mA (at 24 V DC) |
---|
Reverse Polarity Protection | Yes |
---|
Status Indicator (System Supply) | LED green |
---|
Diagnostic Indicator | LED red |
---|
Connection Sensor Supply Voltage | M12 Power, 5-poles, L-coded |
---|
Current Carrying Capacity of Connector | max. 16 A |
---|
Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
---|
Sensor Supply Voltage (Range) | 18 V DC to 30 V DC |
---|
Reverse Polarity Protection | Yes |
---|
Status Indicator (Sensor Supply) | LED green |
---|
Diagnostic Indicator | LED red |
---|
Connection Actuator Supply Voltage | via Module Supply Connection |
---|
Current Carrying Capacity of Connector | max. 16 A |
---|
Actuator Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
---|
Actuator Supply Voltage (Range) | 18 V DC to 30 V DC |
---|
Reverse Polarity Protection | Yes |
---|
Status Indicator (Actuator Supply) | LED green |
---|
Diagnostic Indicator | LED red |
---|
IO-Link Master Channels
Number of IO-Link Master Channels | max. 8, configurable |
---|
Connection | M8, 5-poles, B-coded |
---|
IO-Link Class A Ports | 4x, X1 to X4 |
---|
IO-Link Class B Ports | 4x, X5 to X8 |
---|
IO-Link Specification | V1.1.2 |
---|
Parameter Storage | Supported |
---|
Supported COM Modes | 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3) |
---|
Cycle Time / Update Rate | min. 8 ms for all channels at 32 Byte IN / OUT |
---|
Nominal Current 1L+ (Pin 1) | max. 500 mA (via US) |
---|
Nominal Voltage | 24 V DC via US (system power supply) |
---|
Nominal Current 2L+/Uaux (Pin 2, B Ports) | max. 4 A per module (via Uaux) |
---|
Nominal Current C/Q (Pin 4) | max. 500 mA (via US) |
---|
Perm. Conductor Length to Device | ≤ 20 m |
---|
Status Indicator (IOL) | LED green per channel |
---|
Diagnostic Indicator | LED red per port |
---|
Digital Input Channels
Number of Digital Input Channels | max. 12, configurable |
---|
Connection | M8, 5-poles, B-coded |
---|
Number of Ports | 8x, X1 to X8 |
---|
Channel Type | Type 1 acc. to IEC 61131-2 |
---|
Input Wiring | 2-, 3-wire |
---|
Nominal Voltage | 24 V DC via US (module power supply) |
---|
Nominal Current | typ. 3 mA |
---|
Sensor Current Supply | max. 500 mA per port via 1L+ |
---|
Sensor Type | PNP |
---|
Input Voltage Range "0" signal | -0,3V DC ... 5 V DC |
---|
Input Voltage Range "1" signal | 15 V DC ... 30 V DC |
---|
Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
---|
Status Indicator (Inputs) | LED white or yellow per channel |
---|
Diagnostic Indicator | LED red per port |
---|
Digital Output Channels
Number of Digital Output Channels | max. 8, configurable |
---|
Connection | M8, 5-poles, B-coded |
---|
Number of Ports | 8x, X1 to X8 |
---|
Channel Type | p-switching |
---|
Output Wiring | 2-wire |
---|
Nominal Voltage | 24 V DC via US (system power supply) |
---|
Output Current per Channel | max. 0.5 A (Pin 4) |
---|
Output Current per Module | max. 9 A |
---|
Galvanically Isolated | No |
---|
Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
---|
Overload Behavior | Auto off and on switching / Manual restart |
---|
Status Indicator (Outputs) | LED white or yellow per channel |
---|
Diagnostic Idicator | LED red per port |
---|
Electrical Isolation
US (System Supply Voltage) / FE | 500 V DC |
---|
Uaux / FE | 500 V DC |
---|
Bus connection / FE | 2000 V DC |
---|
EMC Conformance
EMC Directive | 2014/30/EU |
---|
EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
---|
EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
---|
EN 61000-4-4 Fast Transients (Burst) | Criterion B, 2 kV |
---|
EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
---|
EN 61000-4-6 Conducted immunity | Criterion A; Test voltage 10 V |
---|
EN 55022 Radio Interference Properties | Class A |
---|
Safety & Environmental Compliance
CE | Yes |
---|
RoHS Compliant | Yes |
---|
China RoHS-Compliant | Yes |
---|
Approvals
UL | cULus Listed, UL 61010-1 |
---|
UL-File | E230848 |
---|
CSA | Yes, via UL |
---|
PNO | Yes |
---|
ODVA | Yes |
---|
IO-Link | Yes |
---|
Notes
Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
---|
System Power Supply Connection Note | *do not connect / disconnect under voltage! |
---|
Update and Revision | Revision Number: 0.92 Revision Date: 03-04-2023 |
---|
Documentation
Product Bulletins
Flyers
Videos
White Papers
Case Studies
Blogs
Installation Guides
Reference Manuals
Software
Safety Guidance
Technical Information
Product Certifications
Data Sheets