LioN-P, I/O Standalone, Multiprotocol (PROFINET, EtherNet/IP and EtherCAT), industrial metal housing, 60 mm, up to IP67, 8 digital input and 8 digital output channels (2 A) with galvanic isolation, 8 x M12 A-coded I/O connection, 5-poles, 2 x M12 D-coded bus connection, 4-poles, 2 x 7/8" power supply connection, 5-poles
Specifications
Specifications
| Product Family | I/O Systems: Active - Standalone |
|---|
| Product Sub Family | LioN-P |
|---|
| Item Description | 0980 ESL 393-111 |
|---|
| Device Type | I/O Module |
|---|
| Protocol | Multiprotocol |
|---|
| I/O Function | 8DI 8DO |
|---|
| Bus Connection | M12, 4-poles, D-coded |
|---|
| Power Connection (System Supply) | 7/8" Power, 5-poles |
|---|
| I/O Connection | M12, 5-poles, A-coded |
|---|
| I/O Type | Digital Input and Digital Output |
|---|
General Data
| Housing Material | Metal, Zinc Die-cast |
|---|
| Housing Plating | Nickel, matt |
|---|
| Housing Color | Grey Metallic |
|---|
| Protection Degree / IP Rating** | IP65, IP67 |
|---|
| Potted | Yes |
|---|
| Dimensions (W x H x D) | 60 mm x 26 mm x 206 mm |
|---|
| Weight | 520 g |
|---|
| Ambient Temperature (Operation)* | -20 °C to 70 °C |
|---|
| Ambient Temperature (Storage/Transport) | -25 °C to 85 °C |
|---|
| Permissible Humidity (Operation) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Permissible Humidity (Storage/Transport) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Air Pressure (Operation) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Air Pressure (Storage/Transport) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Flammabilty Class | UL 94 (IEC 61010) |
|---|
| Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
|---|
| Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
|---|
| Vibration Resistance | 15 g / 5 -500 Hz |
|---|
| Shock Resistance | 50 g / 11ms |
|---|
| Mean Time To Failure (MTTF) | 633 years. acc. to Telcordia SR-332 (2011) 20°C |
|---|
| Contact Base Material | M12, D-coded, CuSn, Gold-plated | 7/8" CuZn, Gold-plated |
|---|
| Contact Bearer Material | PA / TPU |
|---|
| O-Ring Material | FKM |
|---|
| Mounting | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
|---|
| Fastening Torque (Fixing Screw) | M4: 1 Nm |
|---|
| Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
|---|
| Fastening Torque (Bus Connection) | M12: 0.5 Nm |
|---|
| Fastening Torque (Power Connection) | 7/8": 1.5 Nm |
|---|
| Fastening Torque (I/O Connection) | M12: 0.5 Nm |
|---|
| Included in Delivery | Attachable Labels: 15x, Sealing Caps: 5x M12 |
|---|
PROFINET
| Protocol | PROFINET |
|---|
| Connection | M12 LAN, 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | V2.3X |
|---|
| Conformance Class | C |
|---|
| Performance Class | RT (switch supports IRT) |
|---|
| Netload Class | III |
|---|
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
|---|
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
|---|
| Cycle Time / Update Rate | min. 1 ms |
|---|
| Addressing | DCP |
|---|
| Fast Startup (FSU) | Supported, ≤ 1000 ms |
|---|
| Media Redundancy Protocol (MRP) | Supported, MRP client |
|---|
| Shared Device | Not Supported |
|---|
| Topology Detection | LLDP, SNMP V1 |
|---|
| Easy Device Replacement | Supported, based on LLDP |
|---|
| Supported Network Protocols (Other) | ARP, HTTP, Ping, SNMP V1, TCP/IP |
|---|
EtherNet/IP
| Protocol (EtherNet/IP) | EtherNet/IP |
|---|
| Connection | M12 LAN, 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | CIP V3.1x, EIP Adaption of CIP V1.1x |
|---|
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
|---|
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
|---|
| Cycle Time / Requested Packet Interval (RPI) | min. 1 ms |
|---|
| Addressing | BootP, DHCP, Rotary Address Switches |
|---|
| Address Switches Range | 0 to 255 dec |
|---|
| Connection Types | Exclusive Owner, Input Only, Listen Only |
|---|
| CIP Msg Connection Limit | 6 |
|---|
| CIP I/O Connection Limit | 3 |
|---|
| Device Level Ring (DLR) | Supported, beacon based |
|---|
| Quick Connect (QC) | Supported, ≤ 500 ms |
|---|
| Supported Network Protocols (Other) | ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP |
|---|
EtherCAT
| Protocol | EtherCAT |
|---|
| Connection | M12 LAN, 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | ETG.1000 V1.2 |
|---|
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
|---|
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
|---|
| Cycle Time / Update Rate | min. 250 µs |
|---|
| Addressing | Auto-increment addressing, fixed position addressing |
|---|
| Mailbox Protocols | CANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE) |
|---|
| Supported Network Protocols (Other) | Over EoE: HTTP, Ping, TCP/IP |
|---|
Power Supply
| Connection Module Supply Voltage | 7/8" Power, 5-poles |
|---|
| Number of Connections | 2 |
|---|
| Current Carrying Capacity of Connector | max. 9 A |
|---|
| Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Module Supply Voltage (Range) | 18 V DC to 30 V DC |
|---|
| Current Consumption (typ.) | 120 mA (at 24 V DC) |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (System Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
| Connection Sensor Supply Voltage | M12 Power, 5-poles, L-coded |
|---|
| Current Carrying Capacity of Connector | max. 9 A |
|---|
| Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Sensor Supply Voltage (Range) | 18 V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (Sensor Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
| Connection Actuator Supply Voltage | via Module Supply Connection |
|---|
| Current Carrying Capacity of Connector | max. 9 A |
|---|
| Actuator Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Actuator Supply Voltage (Range) | 18 V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (Actuator Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
Digital Input Channels
| Number of Digital Input Channels | max. 8, fixed |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| Number of Ports | 4x, X1 to X4 |
|---|
| Channel Type | Type 3 acc. to IEC 61131-2 |
|---|
| Input Wiring | 2-, 3-, 4-wire |
|---|
| Nominal Voltage | 24 V DC via US (module power supply) |
|---|
| Nominal Current | typ. 5 mA |
|---|
| Sensor Current Supply | max. 200 mA per port (at 30°C) |
|---|
| Sensor Type | PNP |
|---|
| Input Voltage Range "0" signal | -3 V DC …+5 V DC |
|---|
| Input Voltage Range "1" signal | 11 V DC … 30 V DC |
|---|
| Input Filter Time | 3 ms, fixed |
|---|
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
|---|
| Status Indicator (Inputs) | LED white or yellow per channel |
|---|
| Diagnostic Indicator | LED red per port |
|---|
Digital Output Channels
| Number of Digital Output Channels | max. 8, fixed |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| Number of Ports | 4x, X5 to X8 |
|---|
| Channel Type | p-switching |
|---|
| Output Wiring | 2-, 3-wire |
|---|
| Nominal Voltage | 24 V DC via UL (actuator power supply) |
|---|
| Output Current per Channel | max. 2 A |
|---|
| Output Current per Module | max. 9 A |
|---|
| Galvanically Isolated | Yes |
|---|
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
|---|
| Overload Behavior | Manual restart |
|---|
| Status Indicator (Outputs) | LED white or yellow per channel |
|---|
| Diagnostic Idicator | LED red per channel |
|---|
Electrical Isolation
| US (System Supply Voltage) / FE | 500 V DC |
|---|
| US / UL (Actuator Supply Voltage) | 500 V DC |
|---|
| UL / FE | 500 V DC |
|---|
| Bus connection / FE | 2000 V DC |
|---|
EMC Conformance
| EMC Directive | 2014/30/EU |
|---|
| EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
|---|
| EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
|---|
| EN 61000-4-4 Fast Transients (Burst) | Criterion B, 2 kV |
|---|
| EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
|---|
| EN 61000-4-6 Conducted immunity | Criterion A; Test voltage 10 V |
|---|
| EN 55022 Radio Interference Properties | Class A |
|---|
Safety & Environmental Compliance
| CE | Yes |
|---|
| RoHS Compliant | Yes |
|---|
| China RoHS-Compliant | Yes |
|---|
Approvals
| UL | cULus Listed, UL 61010-1 |
|---|
| UL-File | E230848 |
|---|
| CSA | Yes, via UL |
|---|
| PNO | Yes |
|---|
| ODVA | Yes |
|---|
| ETG | Yes |
|---|
Notes
| Protection Degree / IP Rating Note | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |
|---|
| Update and Revision | Revision Number: 0.92 Revision Date: 05-24-2023 |
|---|
Documentation
Product Bulletins
Case Studies
Blogs
Reference Manuals
Software
Safety Guidance
Technical Information
Product Certifications
Data Sheets