Belden

0980 LSL 3210-121-0006-004 - LioN-Xlight 4xIO-Link Class A, 8DI with EtherCAT

(No reviews yet) Write a Review
SKU:
0980 LSL 3210-121-0006-004
Shipping:
Calculated at Checkout
$0.00

Description

LioN-X IO-Link Master, Single Protocol EtherCAT, IoT Protocol REST, 4 IO-Link Master Ports Class A + 8DI, metal housing IP67, IP69K, 60mm, 8 x M12 A-coded I/O connection 5-poles, 2 x M12 D-coded Ethernet connection 4-poles, 2 x M12 L-coded power supply

Specifications

Specifications

Product FamilyI/O Systems: Active - Standalone
Product Sub FamilyLioN-Xlight
Item Description0980 LSL 3210-121-0006-004
Device TypeIO-Link Master
ProtocolEtherCAT
I/O Function4 IOL (Class A) + 8 DI
Bus ConnectionM12, 4-poles, D-coded
Power Connection (System Supply)M12 Power, 5-poles, L-coded
I/O ConnectionM12, 5-poles, A-coded
I/O TypeIO-Link Master

General Data

Housing MaterialMetal, zinc die-cast
Housing PlatingNickel, matt
Housing ColorGrey Metallic
Protection Degree / IP Rating**IP65, IP67, IP69K
PottedYes
Dimensions (W x H x D)60 mm x 31 mm x 200 mm
Weight500 g
Ambient Temperature (Operation)*-20 °C to 60 °C
Ambient Temperature (Storage/Transport)-20 °C to 60 °C
Permissible Humidity (Operation)5 % ... 95 % (For UL applications max. 80 %)
Permissible Humidity (Storage/Transport)5 % ... 95 % (For UL applications max. 80 %)
Air Pressure (Operation)80 kPa … 106 kPa (up to 2000 m above sea level)
Air Pressure (Storage/Transport)80 kPa … 106 kPa (up to 2000 m above sea level)
Flammabilty ClassUL 94 (IEC 61010)
Protection ClassIII, IEC 61140, EN 61140, VDE 0140-1
Pollution Degree3 acc. to EN 60664-1, VDE 0110-1
Vibration Resistance15 g / 5 -500 Hz
Shock Resistance50 g / 11ms
Contact Base MaterialM12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated
Contact Bearer MaterialPA / TPU
O-Ring MaterialFKM
Mounting2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)M4: 1 Nm
Fastening Torque (Ground Connection (FE))M4: 1 Nm
Fastening Torque (Bus Connection)M12: 0.5 Nm
Fastening Torque (Power Connection)M12: 0.5 Nm
Fastening Torque (I/O Connection)M12: 0.5 Nm
Included in DeliveryAttachable Labels: 15x, Sealing Caps: 5x M12
Accessories to Order SeparatelyEthernet cable, mounting adapter, sensor/actuator cable, power cable

EtherCAT

ProtocolEtherCAT
ConnectionM12 4-poles, D-coded
Number of Connections2
SpecificationETG.1000 V1.2
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Update Ratemin. 250 µs
AddressingAuto-increment addressing, fixed position addressing
Mailbox ProtocolsCANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE), ADS over EtherCAT (AoE)
Supported Network Protocols (Other)Over EoE: HTTP, Ping, TCP/IP

Modbus TCP

REST APICyclic data read/write, Diagnosis data, Event data

Power Supply

Connection Module Supply VoltageM12 Power, 5-poles, L-coded
Number of Connections2
Module Supply Voltage (Nominal)24 V DC (SELV/PELV)
Module Supply Voltage (Range)20V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (System Supply)LED green
Diagnostic IndicatorLED red
Connection Sensor Supply VoltageM12 Power, 5-poles, L-coded
Sensor Supply Voltage (Nominal)24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)20V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (Sensor Supply)LED green
Diagnostic IndicatorLED red

IO-Link Master Channels

Number of IO-Link Master Channelsmax. 4, configurable
ConnectionM12, 5-poles, A-coded
IO-Link Class A Ports4x, X1 to X4
IO-Link SpecificationV1.1.3
Parameter StorageSupported
Supported COM Modes4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3)
Cycle Time / Update Ratemin. 1 ms for all channels at 32 Byte IN / OUT
Nominal Current 1L+ (Pin 1)2A
Nominal Voltage24 V DC via US (system power supply)
Nominal Current C/Q (Pin 4)500mA
Perm. Conductor Length to Device≤ 20 m
Status Indicator (IOL)LED green per channel
Diagnostic IndicatorLED red per port

Digital Input Channels

Number of Digital Input Channelsup to 16
ConnectionM12, 5-poles, A-coded
Number of Ports8x, X1 to X8
Channel TypeType 1 acc. to IEC 61131-2
Input Wiring2-, 3-, 4-wire
Nominal Voltage24 V DC via US (module power supply)
Sensor Current Supplymax. 4A per port via Pin1L+
Sensor TypePNP
Input Voltage Range "0" signal-3 V DC …+5 V DC
Input Voltage Range "1" signal15 V DC ... 30 V DC
Input Filter Timeconfigurable
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Status Indicator (Inputs)LED white or yellow per channel
Diagnostic IndicatorLED red per port

Digital Output Channels

Number of Digital Output Channelsup to 4
ConnectionM12, 5-poles, A-coded
Number of Ports8x, X1 to X4
Channel Typep-switching
Output Wiring2-, 3-wire
Nominal Voltage24 V DC via US
Output Current per Channelmax. 500mA
Galvanically IsolatedNo
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Overload BehaviorAuto off and on switching / Manual restart
Status Indicator (Outputs)LED white or yellow per channel
Diagnostic IdicatorLED red per port

Electrical Isolation

US (System Supply Voltage) / FE500 V DC
US / UL (Actuator Supply Voltage)500 V DC
UL / FE500 V DC
Uaux / FE500 V DC
Bus connection / FE2000 V DC

EMC Conformance

EMC Directive2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic FieldCriterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)Criterion B, 2 kV
EN 61000-4-5 Surge VoltageCriterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunityCriterion A; Test voltage 10 V
EN 55032 Radio Interference PropertiesClass A

Safety & Environmental Compliance

CEYes
RoHS CompliantYes
China RoHS-CompliantYes

Approvals

ULcULus Listed, UL 61010-1
CSAYes, via UL
ETGYes
IO-LinkYes

Notes

Protection Degree / IP Rating Note*only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!
Update and RevisionRevision Number: 0.117 Revision Date: 07-20-2023

Documentation

Product Bulletins

Flyers

Videos

White Papers

Case Studies

Blogs

Software

Product Certifications

Reference Manuals

Technical Information

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Item Description
Variant_Options 935702003:
935702003|0980 LSL 3210-121-0006-004
View AllClose