LioN-X IO-Link Master, Single Protocol Modbus TCP, IoT Protocol REST, 8 IO-Link Master Ports Class A, metal housing IP67, IP69K, 60mm, 8 x M12 A-coded I/O connection 5-poles, 2 x M12 D-coded Ethernet connection 4-poles, 2 x M12 L-coded power supply
Specifications
Specifications
| Product Family | I/O Systems: Active - Standalone |
|---|
| Product Sub Family | LioN-Xlight |
|---|
| Item Description | 0980 LSL 3311-121-0006-008 |
|---|
| Device Type | IO-Link Master |
|---|
| Protocol | Modbus TCP |
|---|
| I/O Function | 8 IOL (Class A) |
|---|
| Bus Connection | M12, 4-poles, D-coded |
|---|
| Power Connection (System Supply) | M12 Power, 5-poles, L-coded |
|---|
| I/O Connection | M12, 5-poles, A-coded |
|---|
| I/O Type | IO-Link Master |
|---|
General Data
| Housing Material | Metal, zinc die-cast |
|---|
| Housing Plating | Nickel, matt |
|---|
| Housing Color | Grey Metallic |
|---|
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
|---|
| Potted | Yes |
|---|
| Dimensions (W x H x D) | 60 mm x 31 mm x 200 mm |
|---|
| Weight | 500 g |
|---|
| Ambient Temperature (Operation)* | -20 °C to 60 °C |
|---|
| Ambient Temperature (Storage/Transport) | -20 °C to 60 °C |
|---|
| Permissible Humidity (Operation) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Permissible Humidity (Storage/Transport) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Air Pressure (Operation) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Air Pressure (Storage/Transport) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Flammabilty Class | UL 94 (IEC 61010) |
|---|
| Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
|---|
| Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
|---|
| Vibration Resistance | 15 g / 5 -500 Hz |
|---|
| Shock Resistance | 50 g / 11ms |
|---|
| Contact Base Material | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
|---|
| Contact Bearer Material | PA / TPU |
|---|
| O-Ring Material | FKM |
|---|
| Mounting | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
|---|
| Fastening Torque (Fixing Screw) | M4: 1 Nm |
|---|
| Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
|---|
| Fastening Torque (Bus Connection) | M12: 0.5 Nm |
|---|
| Fastening Torque (Power Connection) | M12: 0.5 Nm |
|---|
| Fastening Torque (I/O Connection) | M12: 0.5 Nm |
|---|
| Included in Delivery | Attachable Labels: 15x, Sealing Caps: 5x M12 |
|---|
| Accessories to Order Separately | Ethernet cable, mounting adapter, sensor/actuator cable, power cable |
|---|
Modbus TCP
| Protocol | Modbus TCP |
|---|
| Connection | M12, 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Device Type | Modbus Slave |
|---|
| Specification | Modbus application protocol V1.1b |
|---|
| REST API | Cyclic data read/write, Diagnosis data, Event data |
|---|
Power Supply
| Connection Module Supply Voltage | M12 Power, 5-poles, L-coded |
|---|
| Number of Connections | 2 |
|---|
| Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Module Supply Voltage (Range) | 20V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (System Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
| Connection Sensor Supply Voltage | M12 Power, 5-poles, L-coded |
|---|
| Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Sensor Supply Voltage (Range) | 20V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (Sensor Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
IO-Link Master Channels
| Number of IO-Link Master Channels | max. 8, configurable |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| IO-Link Class A Ports | 8x, X1 to X8 |
|---|
| IO-Link Specification | V1.1.3 |
|---|
| Parameter Storage | Supported |
|---|
| Supported COM Modes | 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3) |
|---|
| Cycle Time / Update Rate | min. 1 ms for all channels at 32 Byte IN / OUT |
|---|
| Nominal Current 1L+ (Pin 1) | 2A |
|---|
| Nominal Voltage | 24 V DC via US (system power supply) |
|---|
| Nominal Current C/Q (Pin 4) | 500mA |
|---|
| Perm. Conductor Length to Device | ≤ 20 m |
|---|
| Status Indicator (IOL) | LED green per channel |
|---|
| Diagnostic Indicator | LED red per port |
|---|
Digital Input Channels
| Number of Digital Input Channels | up to 16 |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| Number of Ports | 8x, X1 to X8 |
|---|
| Channel Type | Type 1 acc. to IEC 61131-2 |
|---|
| Input Wiring | 2-, 3-, 4-wire |
|---|
| Nominal Voltage | 24 V DC via US (module power supply) |
|---|
| Sensor Current Supply | max. 4A per port via Pin1L+ |
|---|
| Sensor Type | PNP |
|---|
| Input Voltage Range "0" signal | -3 V DC …+5 V DC |
|---|
| Input Voltage Range "1" signal | 15 V DC ... 30 V DC |
|---|
| Input Filter Time | configurable |
|---|
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
|---|
| Status Indicator (Inputs) | LED white or yellow per channel |
|---|
| Diagnostic Indicator | LED red per port |
|---|
Digital Output Channels
| Number of Digital Output Channels | up to 8 |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| Number of Ports | 8x, X1 to X8 |
|---|
| Channel Type | p-switching |
|---|
| Output Wiring | 2-, 3-wire |
|---|
| Nominal Voltage | 24 V DC via US |
|---|
| Output Current per Channel | max. 500mA |
|---|
| Galvanically Isolated | No |
|---|
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
|---|
| Overload Behavior | Auto off and on switching / Manual restart |
|---|
| Status Indicator (Outputs) | LED white or yellow per channel |
|---|
| Diagnostic Idicator | LED red per port |
|---|
Electrical Isolation
| US (System Supply Voltage) / FE | 500 V DC |
|---|
| US / UL (Actuator Supply Voltage) | 500 V DC |
|---|
| UL / FE | 500 V DC |
|---|
| Uaux / FE | 500 V DC |
|---|
| Bus connection / FE | 2000 V DC |
|---|
EMC Conformance
| EMC Directive | 2014/30/EU |
|---|
| EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
|---|
| EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
|---|
| EN 61000-4-4 Fast Transients (Burst) | Criterion B, 2 kV |
|---|
| EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
|---|
| EN 61000-4-6 Conducted immunity | Criterion A; Test voltage 10 V |
|---|
| EN 55032 Radio Interference Properties | Class A |
|---|
Safety & Environmental Compliance
| CE | Yes |
|---|
| RoHS Compliant | Yes |
|---|
| China RoHS-Compliant | Yes |
|---|
Approvals
| UL | cULus Listed, UL 61010-1 |
|---|
| CSA | Yes, via UL |
|---|
| IO-Link | Yes |
|---|
Notes
| Protection Degree / IP Rating Note | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |
|---|
| Update and Revision | Revision Number: 0.114 Revision Date: 07-20-2023 |
|---|
Documentation
Product Bulletins
Flyers
Videos
White Papers
Case Studies
Blogs
Technical Information
Product Certifications
Software
Reference Manuals
Data Sheets