LioN-X IO-Link Master, Multiprotocol (PROFINET, EtherNet/IP, EtherCAT, Modbus TCP, CC-Link IE Field Basic), IoT Protocols (OPC UA, MQTT, CoAP, REST), 8 IO-Link Master Ports Class A, metal housing IP67, IP69K, 60mm, 8 x M12 A-coded I/O connection 5-poles, 2 x M12 D-coded Ethernet connection 4-poles, 2 x M12 L-coded power supply
Specifications
Specifications
| Product Family | I/O Systems: Active - Standalone |
|---|
| Product Sub Family | LioN-X |
|---|
| Item Description | 0980 XSL 3912-121-007D-01F |
|---|
| Device Type | IO-Link Master |
|---|
| Protocol | Multiprotocol |
|---|
| I/O Function | 8 IOL (Class A) |
|---|
| Bus Connection | M12, 4-poles, D-coded |
|---|
| Power Connection (System Supply) | M12 Power, 5-poles, L-coded |
|---|
| I/O Connection | M12, 5-poles, A-coded |
|---|
| I/O Type | IO-Link Master |
|---|
General Data
| Housing Material | Metal, zinc die-cast |
|---|
| Housing Plating | Nickel, matt |
|---|
| Housing Color | Grey Metallic |
|---|
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
|---|
| Potted | Yes |
|---|
| Dimensions (W x H x D) | 60 mm x 31 mm x 200 mm |
|---|
| Weight | 480 g |
|---|
| Ambient Temperature (Operation)* | -40 °C to 70 °C |
|---|
| Ambient Temperature (Storage/Transport) | -40 °C to 70 °C |
|---|
| Permissible Humidity (Operation) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Permissible Humidity (Storage/Transport) | 5 % ... 95 % (For UL applications max. 80 %) |
|---|
| Air Pressure (Operation) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Air Pressure (Storage/Transport) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
|---|
| Flammabilty Class | UL 94 (IEC 61010) |
|---|
| Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
|---|
| Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
|---|
| Vibration Resistance | 15 g / 5 -500 Hz |
|---|
| Shock Resistance | 50 g / 11ms |
|---|
| Mean Time Between Failures (MTBF) | 4616848 |
|---|
| Contact Base Material | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
|---|
| Contact Bearer Material | PA / TPU |
|---|
| O-Ring Material | FKM |
|---|
| Mounting | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
|---|
| Fastening Torque (Fixing Screw) | M4: 1 Nm |
|---|
| Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
|---|
| Fastening Torque (Bus Connection) | M12: 0.5 Nm |
|---|
| Fastening Torque (Power Connection) | M12: 0.5 Nm |
|---|
| Fastening Torque (I/O Connection) | M12: 0.5 Nm |
|---|
| Included in Delivery | Attachable Labels: 15x, Sealing Caps: 5x M12 |
|---|
| Accessories to Order Separately | Ethernet cable, mounting adapter, sensor/actuator cable, power cable |
|---|
PROFINET
| Protocol | PROFINET |
|---|
| Connection | M12 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | V2.3 |
|---|
| Conformance Class | C (CC-C) |
|---|
| Performance Class | RT (switch supports IRT) |
|---|
| Netload Class | III |
|---|
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
|---|
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
|---|
| Cycle Time / Update Rate | min. 1 ms |
|---|
| Addressing | DCP |
|---|
| Media Redundancy Protocol (MRP) | Supported, MRP client |
|---|
| Shared Device | Supported |
|---|
| Shared Input | not supported |
|---|
| Topology Detection | LLDP, SNMP V3 |
|---|
| Easy Device Replacement | Supported, based on LLDP |
|---|
| Supported Network Protocols (Other) | ARP, HTTP, Ping, SNMP V1, TCP/IP |
|---|
EtherNet/IP
| Protocol (EtherNet/IP) | EtherNet/IP |
|---|
| Connection | M12, 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | CIP V3.2x, EIP Adaption of CIP V1.2x |
|---|
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
|---|
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
|---|
| Cycle Time / Requested Packet Interval (RPI) | min. 1 ms |
|---|
| Addressing | BootP, DHCP, Rotary Address Switches |
|---|
| Address Switches Range | 0 to 255 dec |
|---|
| Connection Types | Exclusive Owner, Input Only, Listen Only |
|---|
| CIP Msg Connection Limit | 6 |
|---|
| CIP I/O Connection Limit | 3 |
|---|
| Device Level Ring (DLR) | Supported, beacon based |
|---|
| Quick Connect (QC) | Supported, ≤ 500 ms |
|---|
| Supported Network Protocols (Other) | ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP |
|---|
EtherCAT
| Protocol | EtherCAT |
|---|
| Connection | M12 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | ETG.1000 V1.2 |
|---|
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
|---|
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
|---|
| Cycle Time / Update Rate | min. 250 µs |
|---|
| Addressing | Auto-increment addressing, fixed position addressing |
|---|
| Mailbox Protocols | CANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE) |
|---|
| Supported Network Protocols (Other) | Over EoE: HTTP, Ping, TCP/IP |
|---|
CC-Link IE Field Basic
| Protocol | CC-Link IE Field Basic |
|---|
| Connection | M12 LAN, 4-poles. D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | v2 |
|---|
| Transmission Rate | Fast Ethernet (100 Mbit/s), Full Duplex |
|---|
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
|---|
| Cycle Time / Update Rate | min 1ms |
|---|
| Address Switches Range | 0 to 99 dec |
|---|
| Number of stations | 4 |
|---|
| Supported Network Protocols | SNMP, ACD, ARP, HTTP, IGMP, Ping, TCP/IP |
|---|
| Supported IIoT Protocols | OPC UA, MQTT, CoAP, Syslog, Node Red |
|---|
Modbus TCP
| Protocol | Modbus TCP |
|---|
| Connection | M12, 4-poles, D-coded |
|---|
| Number of Connections | 2 |
|---|
| Specification | Modbus application protocol V1.1b |
|---|
| OPC UA | Cyclic data read/write, Diagnosis data, Event data |
|---|
| MQTT | Cyclic data read/write, Diagnosis data, Event data |
|---|
| REST API | Cyclic data read/write, Diagnosis data, Event data |
|---|
| CoAP | Cyclic data read/write, Diagnosis data, Event data |
|---|
IO-Links
| Protocol | IO-Link Master |
|---|
| Connection | M12 5-poles, A-coded |
|---|
| Number of Connections | 8 |
|---|
| Specification | v1.1.3 ready, IEC 61131-9 |
|---|
| IO-Link Class | Class A |
|---|
| Transmission Rate / COM Mode | COM1, COM2, COM3 |
|---|
| Parameter Storage | supported |
|---|
Power Supply
| Connection Module Supply Voltage | M12 Power, 5-poles, L-coded |
|---|
| Number of Connections | 2 |
|---|
| Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Module Supply Voltage (Range) | 20V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (System Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
| Connection Sensor Supply Voltage | M12 Power, 5-poles, L-coded |
|---|
| Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Sensor Supply Voltage (Range) | 20V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (Sensor Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
| Actuator Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
|---|
| Actuator Supply Voltage (Range) | 18 V DC to 30 V DC |
|---|
| Reverse Polarity Protection | Yes |
|---|
| Status Indicator (Actuator Supply) | LED green |
|---|
| Diagnostic Indicator | LED red |
|---|
IO-Link Master Channels
| Number of IO-Link Master Channels | max. 8, configurable |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| IO-Link Class A Ports | 8x, X1 to X8 |
|---|
| IO-Link Specification | V1.1.3 |
|---|
| Parameter Storage | Supported |
|---|
| Supported COM Modes | 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3) |
|---|
| Cycle Time / Update Rate | min. 1 ms for all channels at 32 Byte IN / OUT |
|---|
| Nominal Current 1L+ (Pin 1) | 4A |
|---|
| Nominal Voltage | 24 V DC via US (system power supply) |
|---|
| Nominal Current C/Q (Pin 4) | 500mA |
|---|
| Perm. Conductor Length to Device | ≤ 20 m |
|---|
| Status Indicator (IOL) | LED green per channel |
|---|
| Diagnostic Indicator | LED red per port |
|---|
Digital Input Channels
| Number of Digital Input Channels | up to 16 |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| Number of Ports | 8x, X1 to X8 |
|---|
| Channel Type | Type 1 acc. to IEC 61131-2 |
|---|
| Input Wiring | 2-, 3-, 4-wire |
|---|
| Nominal Voltage | 24 V DC via US (module power supply) |
|---|
| Sensor Type | PNP |
|---|
| Input Voltage Range "0" signal | -3 V DC …+5 V DC |
|---|
| Input Voltage Range "1" signal | 15 V DC ... 30 V DC |
|---|
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
|---|
| Status Indicator (Inputs) | LED white or yellow per channel |
|---|
| Diagnostic Indicator | LED red per port |
|---|
Digital Output Channels
| Number of Digital Output Channels | up to 16 |
|---|
| Connection | M12, 5-poles, A-coded |
|---|
| Number of Ports | 8x, X1 to X8 |
|---|
| Channel Type | p-switching |
|---|
| Output Wiring | 2-, 3-wire |
|---|
| Nominal Voltage | 24 V DC via UL |
|---|
| Output Current per Channel | max. 2 A |
|---|
| Output Current per Module | max. 16 A (for UL compliance: max 9A) |
|---|
| Galvanically Isolated | No |
|---|
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
|---|
| Overload Behavior | Auto off and on switching / Manual restart |
|---|
| Status Indicator (Outputs) | LED white or yellow per channel |
|---|
| Diagnostic Idicator | LED red per port |
|---|
Electrical Isolation
| US (System Supply Voltage) / FE | 500 V DC |
|---|
| US / UL (Actuator Supply Voltage) | 500 V DC |
|---|
| UL / FE | 500 V DC |
|---|
| Bus connection / FE | 2000 V DC |
|---|
EMC Conformance
| EMC Directive | 2014/30/EU |
|---|
| EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
|---|
| EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
|---|
| EN 61000-4-4 Fast Transients (Burst) | Criterion B, 2 kV |
|---|
| EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
|---|
| EN 61000-4-6 Conducted immunity | Criterion A; Test voltage 10 V |
|---|
| EN 55032 Radio Interference Properties | Class A |
|---|
Safety & Environmental Compliance
| CE | Yes |
|---|
| RoHS Compliant | Yes |
|---|
| China RoHS-Compliant | Yes |
|---|
Approvals
| UL | cULus Listed, UL 61010-1 |
|---|
| CSA | Yes, via UL |
|---|
| PNO | Yes |
|---|
| ODVA | Yes |
|---|
| ETG | Yes |
|---|
| IO-Link | Yes |
|---|
Notes
| Protection Degree / IP Rating Note | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
|---|
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |
|---|
| Update and Revision | Revision Number: 0.47 Revision Date: 07-20-2023 |
|---|