LioN-X IO-Link Master, Multiprotocol (PROFINET, EtherNet/IP, EtherCAT, Modbus TCP, CC-Link), IoT Protocols (OPC UA, MQTT, CoAP, REST), 4 IO-Link Master Ports Class A, 4 IO-Link Master Ports Class B, metal housing IP65, IP67, IP69K, 60mm, 8 x M12 A-coded I/O connection 5-poles, 2 x M12 D-coded Ethernet connection 4-poles, 2 x M12 L-coded power supply
Specifications
Specifications
Product Family | I/O Systems: Active - Standalone |
---|
Product Sub Family | LioN-X |
---|
Item Description | 0980 XSL 3913-121-007D-01F |
---|
Device Type | IO-Link Master |
---|
Protocol | Multiprotocol |
---|
I/O Function | 4 IOL (Class A) + 4 IOL (Class B) |
---|
Bus Connection | M12, 4-poles, D-coded |
---|
Power Connection (System Supply) | M12 Power, 5-poles, L-coded |
---|
I/O Connection | M12, 5-poles, A-coded |
---|
I/O Type | IO-Link Master |
---|
General Data
Housing Material | Metal, zinc die-cast |
---|
Housing Plating | Nickel, matt |
---|
Housing Color | Grey Metallic |
---|
Protection Degree / IP Rating** | IP65, IP67, IP69K |
---|
Potted | Yes |
---|
Dimensions (W x H x D) | 60 mm x 31 mm x 200 mm |
---|
Weight | 480 g |
---|
Ambient Temperature (Operation)* | -40 °C to 70 °C |
---|
Ambient Temperature (Storage/Transport) | -40 °C to 70 °C |
---|
Permissible Humidity (Operation) | 5 % ... 95 % (For UL applications max. 80 %) |
---|
Permissible Humidity (Storage/Transport) | 5 % ... 95 % (For UL applications max. 80 %) |
---|
Air Pressure (Operation) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
---|
Air Pressure (Storage/Transport) | 80 kPa … 106 kPa (up to 2000 m above sea level) |
---|
Flammabilty Class | UL 94 (IEC 61010) |
---|
Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
---|
Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
---|
Vibration Resistance | 15 g / 5 -500 Hz |
---|
Shock Resistance | 50 g / 11ms |
---|
Mean Time Between Failures (MTBF) | 4604052 |
---|
Contact Base Material | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
---|
Contact Bearer Material | PA / TPU |
---|
O-Ring Material | FKM |
---|
Mounting | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
---|
Fastening Torque (Fixing Screw) | M4: 1 Nm |
---|
Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
---|
Fastening Torque (Bus Connection) | M12: 0.5 Nm |
---|
Fastening Torque (Power Connection) | M12: 0.5 Nm |
---|
Fastening Torque (I/O Connection) | M12: 0.5 Nm |
---|
Included in Delivery | Attachable Labels: 15x, Sealing Caps: 5x M12 |
---|
Accessories to Order Separately | Ethernet cable, mounting adapter, sensor/actuator cable, power cable |
---|
PROFINET
Protocol | PROFINET |
---|
Connection | M12 4-poles, D-coded |
---|
Number of Connections | 2 |
---|
Specification | V2.3 |
---|
Conformance Class | C (CC-C) |
---|
Performance Class | RT (switch supports IRT) |
---|
Netload Class | III |
---|
Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
---|
Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
---|
Cycle Time / Update Rate | min. 1 ms |
---|
Addressing | DCP |
---|
Media Redundancy Protocol (MRP) | Supported, MRP client |
---|
Shared Device | Supported |
---|
Shared Input | not supported |
---|
Topology Detection | LLDP, SNMP V3 |
---|
Easy Device Replacement | Supported, based on LLDP |
---|
Supported Network Protocols (Other) | ARP, HTTP, Ping, SNMP V1, TCP/IP |
---|
EtherNet/IP
Protocol (EtherNet/IP) | EtherNet/IP |
---|
Connection | M12, 4-poles, D-coded |
---|
Number of Connections | 2 |
---|
Specification | CIP V3.2x, EIP Adaption of CIP V1.2x |
---|
Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
---|
Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
---|
Cycle Time / Requested Packet Interval (RPI) | min. 1 ms |
---|
Addressing | BootP, DHCP, Rotary Address Switches |
---|
Address Switches Range | 0 to 255 dec |
---|
Connection Types | Exclusive Owner, Input Only, Listen Only |
---|
CIP Msg Connection Limit | 6 |
---|
CIP I/O Connection Limit | 3 |
---|
Device Level Ring (DLR) | Supported, beacon based |
---|
Quick Connect (QC) | Supported, ≤ 500 ms |
---|
Supported Network Protocols (Other) | ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP |
---|
EtherCAT
Protocol | EtherCAT |
---|
Connection | M12 4-poles, D-coded |
---|
Number of Connections | 2 |
---|
Specification | ETG.1000 V1.2 |
---|
Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
---|
Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
---|
Cycle Time / Update Rate | min. 250 µs |
---|
Addressing | Auto-increment addressing, fixed position addressing |
---|
Mailbox Protocols | CANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE) |
---|
Supported Network Protocols (Other) | Over EoE: HTTP, Ping, TCP/IP |
---|
CC-Link IE Field Basic
Protocol | CC-Link IE Field Basic |
---|
Connection | M12 LAN, 4-poles. D-coded |
---|
Number of Connections | 2 |
---|
Specification | v2 |
---|
Transmission Rate | Fast Ethernet (100 Mbit/s), Full Duplex |
---|
Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
---|
Cycle Time / Update Rate | min 1ms |
---|
Address Switches Range | 0 to 99 dec |
---|
Number of stations | 4 |
---|
Supported Network Protocols | SNMP, ACD, ARP, HTTP, IGMP, Ping, TCP/IP |
---|
Supported IIoT Protocols | OPC UA, MQTT, CoAP, Syslog, Node Red |
---|
Modbus TCP
Protocol | Modbus TCP |
---|
Connection | M12, 4-poles, D-coded |
---|
Number of Connections | 2 |
---|
Specification | Modbus application protocol V1.1b |
---|
OPC UA | Cyclic data read/write, Diagnosis data, Event data |
---|
MQTT | Cyclic data read/write, Diagnosis data, Event data |
---|
REST API | Cyclic data read/write, Diagnosis data, Event data |
---|
CoAP | Cyclic data read/write, Diagnosis data, Event data |
---|
IO-Links
Protocol | IO-Link Master |
---|
Connection | M12 5-poles, A-coded |
---|
Number of Connections | 8 |
---|
Specification | v1.1.3 ready, IEC 61131-9 |
---|
IO-Link Class | Class A + Class B |
---|
Transmission Rate / COM Mode | COM1, COM2, COM3 |
---|
Parameter Storage | supported |
---|
Power Supply
Connection Module Supply Voltage | M12 Power, 5-poles, L-coded |
---|
Number of Connections | 2 |
---|
Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
---|
Module Supply Voltage (Range) | 20V DC to 30 V DC |
---|
Reverse Polarity Protection | Yes |
---|
Status Indicator (System Supply) | LED green |
---|
Diagnostic Indicator | LED red |
---|
Connection Sensor Supply Voltage | M12 Power, 5-poles, L-coded |
---|
Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
---|
Sensor Supply Voltage (Range) | 20V DC to 30 V DC |
---|
Reverse Polarity Protection | Yes |
---|
Status Indicator (Sensor Supply) | LED green |
---|
Diagnostic Indicator | LED red |
---|
Actuator Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
---|
Actuator Supply Voltage (Range) | 18 V DC to 30 V DC |
---|
Reverse Polarity Protection | Yes |
---|
Status Indicator (Actuator Supply) | LED green |
---|
Diagnostic Indicator | LED red |
---|
IO-Link Master Channels
Number of IO-Link Master Channels | max. 8, configurable |
---|
Connection | M12, 5-poles, A-coded |
---|
IO-Link Class A Ports | 4x, X1 to X4 |
---|
IO-Link Class B Ports | 4x, X5 to X8 |
---|
IO-Link Specification | V1.1.3 |
---|
Parameter Storage | Supported |
---|
Supported COM Modes | 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3) |
---|
Cycle Time / Update Rate | min. 1 ms for all channels at 32 Byte IN / OUT |
---|
Nominal Current 1L+ (Pin 1) | 4A |
---|
Nominal Voltage | 24 V DC via US (system power supply) |
---|
Nominal Current 2L+/Uaux (Pin 2, B Ports) | 2A |
---|
Nominal Current C/Q (Pin 4) | 500mA |
---|
Perm. Conductor Length to Device | ≤ 20 m |
---|
Status Indicator (IOL) | LED green per channel |
---|
Diagnostic Indicator | LED red per port |
---|
Digital Input Channels
Number of Digital Input Channels | up to 12 |
---|
Connection | M12, 5-poles, A-coded |
---|
Number of Ports | 8x, X1 to X8 |
---|
Channel Type | Type 1 acc. to IEC 61131-2 |
---|
Input Wiring | 2-, 3-, 4-wire |
---|
Nominal Voltage | 24 V DC via US (module power supply) |
---|
Sensor Type | PNP |
---|
Input Voltage Range "0" signal | -3 V DC …+5 V DC |
---|
Input Voltage Range "1" signal | 15 V DC ... 30 V DC |
---|
Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
---|
Status Indicator (Inputs) | LED white or yellow per channel |
---|
Diagnostic Indicator | LED red per port |
---|
Digital Output Channels
Number of Digital Output Channels | up to 16 |
---|
Connection | M12, 5-poles, A-coded |
---|
Number of Ports | 8x, X1 to X8 |
---|
Channel Type | p-switching |
---|
Output Wiring | 2-, 3-wire |
---|
Nominal Voltage | 24 V DC 12x via US + 4x via Uaux |
---|
Output Current per Channel | max. 2 A |
---|
Output Current per Module | max. 16 A (for UL compliance: max 9A) |
---|
Galvanically Isolated | YES |
---|
Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
---|
Overload Behavior | Auto off and on switching / Manual restart |
---|
Status Indicator (Outputs) | LED white or yellow per channel |
---|
Diagnostic Idicator | LED red per port |
---|
Electrical Isolation
US (System Supply Voltage) / FE | 500 V DC |
---|
Uaux / FE | 500 V DC |
---|
Bus connection / FE | 2000 V DC |
---|
EMC Conformance
EMC Directive | 2014/30/EU |
---|
EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
---|
EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
---|
EN 61000-4-4 Fast Transients (Burst) | Criterion B, 2 kV |
---|
EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
---|
EN 61000-4-6 Conducted immunity | Criterion A; Test voltage 10 V |
---|
EN 55032 Radio Interference Properties | Class A |
---|
Safety & Environmental Compliance
CE | Yes |
---|
RoHS Compliant | Yes |
---|
China RoHS-Compliant | Yes |
---|
Approvals
UL | cULus Listed, UL 61010-1 |
---|
CSA | Yes, via UL |
---|
PNO | Yes |
---|
ODVA | Yes |
---|
ETG | Yes |
---|
IO-Link | Yes |
---|
Notes
Protection Degree / IP Rating Note | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
---|
System Power Supply Connection Note | *do not connect / disconnect under voltage! |
---|
Update and Revision | Revision Number: 0.39 Revision Date: 07-20-2023 |
---|
Documentation
Product Bulletins
Flyers
Videos
White Papers
Case Studies
Blogs
Software
Reference Manuals
Product Certifications
Data Sheets