Belden

0980 XSL 3923-121-007D-01F - LioN-X 8DI/8DO Digital without galvanic isolation, Multip.

(No reviews yet) Write a Review
SKU:
0980 XSL 3923-121-007D-01F
Shipping:
Calculated at Checkout
$0.00

Description

LioN-X IO-Device, Multiprotocol (PROFINET, EtherNet/IP, EtherCAT, Modbus TCP, CC-Link), IoT Protocols (OPC UA, MQTT, CoAP, REST), 8 digital input and 8 digital output channels (2 A) without galvanic isolation, metal housing IP65, IP67, IP69K, 60mm, 8 x M12 A-coded I/O connection 5-poles, 2 x M12 D-coded Ethernet connection 4-poles, 2 x M12 L-coded power supply

Specifications

Specifications

Product FamilyI/O Systems: Active - Standalone
Product Sub FamilyLioN-X
Item Description0980 XSL 3923-121-007D-01F
Device TypeI/O Device
ProtocolMultiprotocol
I/O Function8DI 8DO
Bus ConnectionM12, 4-poles, D-coded
Power Connection (System Supply)M12 Power, 5-poles, L-coded
I/O ConnectionM12, 5-poles, A-coded
I/O TypeDigital Input and Digital Output

General Data

Housing MaterialMetal, zinc die-cast
Housing PlatingNickel, matt
Housing ColorGrey Metallic
Protection Degree / IP Rating**IP65, IP67, IP69K
PottedYes
Dimensions (W x H x D)60 mm x 31 mm x 200 mm
Weight480 g
Ambient Temperature (Operation)*-40 °C to 70 °C
Ambient Temperature (Storage/Transport)-40 °C to 70 °C
Permissible Humidity (Operation)5 % ... 95 % (For UL applications max. 80 %)
Permissible Humidity (Storage/Transport)5 % ... 95 % (For UL applications max. 80 %)
Air Pressure (Operation)80 kPa … 106 kPa (up to 2000 m above sea level)
Air Pressure (Storage/Transport)80 kPa … 106 kPa (up to 2000 m above sea level)
Flammabilty ClassUL 94 (IEC 61010)
Protection ClassIII, IEC 61140, EN 61140, VDE 0140-1
Pollution Degree3 acc. to EN 60664-1, VDE 0110-1
Vibration Resistance15 g / 5 -500 Hz
Shock Resistance50 g / 11ms
Contact Base MaterialM12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated
Contact Bearer MaterialPA / TPU
O-Ring MaterialFKM
Mounting2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)M4: 1 Nm
Fastening Torque (Ground Connection (FE))M4: 1 Nm
Fastening Torque (Bus Connection)M12: 0.5 Nm
Fastening Torque (Power Connection)M12: 0.5 Nm
Fastening Torque (I/O Connection)M12: 0.5 Nm
Included in DeliveryAttachable Labels: 15x, Sealing Caps: 5x M12
Accessories to Order SeparatelyEthernet cable, mounting adapter, sensor/actuator cable, power cable

PROFINET

ProtocolPROFINET
ConnectionM12 4-poles, D-coded
Number of Connections2
SpecificationV2.3
Conformance ClassC (CC-C)
Performance ClassRT (switch supports IRT)
Netload ClassIII
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Update Ratemin. 1 ms
AddressingDCP
Media Redundancy Protocol (MRP)Supported, MRP client
Shared DeviceSupported
Shared Inputnot supported
Topology DetectionLLDP, SNMP V3
Easy Device ReplacementSupported, based on LLDP
Supported Network Protocols (Other)ARP, HTTP, Ping, SNMP V1, TCP/IP

EtherNet/IP

Protocol (EtherNet/IP)EtherNet/IP
ConnectionM12, 4-poles, D-coded
Number of Connections2
SpecificationCIP V3.2x, EIP Adaption of CIP V1.2x
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Requested Packet Interval (RPI)min. 1 ms
AddressingBootP, DHCP, Rotary Address Switches
Address Switches Range0 to 255 dec
Connection TypesExclusive Owner, Input Only, Listen Only
CIP Msg Connection Limit6
CIP I/O Connection Limit3
Device Level Ring (DLR)Supported, beacon based
Quick Connect (QC)Supported, ≤ 500 ms
Supported Network Protocols (Other)ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP

EtherCAT

ProtocolEtherCAT
ConnectionM12 4-poles, D-coded
Number of Connections2
SpecificationETG.1000 V1.2
Transmission RateFast Ethernet (10/100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Update Ratemin. 250 µs
AddressingAuto-increment addressing, fixed position addressing
Mailbox ProtocolsCANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE)
Supported Network Protocols (Other)Over EoE: HTTP, Ping, TCP/IP

CC-Link IE Field Basic

ProtocolCC-Link IE Field Basic
ConnectionM12 LAN, 4-poles. D-coded
Number of Connections2
Specificationv2
Transmission RateFast Ethernet (100 Mbit/s), Full Duplex
Transmission Method100 BASE-TX, with auto negotiation and auto crossing
Cycle Time / Update Ratemin 1ms
Address Switches Range0 to 99 dec
Number of stations4
Supported Network ProtocolsSNMP, ACD, ARP, HTTP, IGMP, Ping, TCP/IP
Supported IIoT ProtocolsOPC UA, MQTT, CoAP, Syslog, Node Red

Modbus TCP

ProtocolModbus TCP
ConnectionM12, 4-poles, D-coded
Number of Connections2
Device TypeModbus Slave
SpecificationModbus application protocol V1.1b
Supported Network ProtocolsSNMP V1, HTTP, TFTP, FTP, BootP, DHCP
OPC UACyclic data read/write, Diagnosis data, Event data
MQTTCyclic data read/write, Diagnosis data, Event data
REST APICyclic data read/write, Diagnosis data, Event data
CoAPCyclic data read/write, Diagnosis data, Event data

Power Supply

Connection Module Supply VoltageM12 Power, 5-poles, L-coded
Number of Connections2
Current Carrying Capacity of Connectormax. 16 A
Module Supply Voltage (Nominal)24 V DC (SELV/PELV)
Module Supply Voltage (Range)18 V DC to 30 V DC
Current Consumption (typ.)140mA (at 24V DC, US max. 1A with sensor load)
Reverse Polarity ProtectionYes
Status Indicator (System Supply)LED green
Diagnostic IndicatorLED red
Connection Sensor Supply VoltageM12 Power, 5-poles, L-coded
Current Carrying Capacity of Connectormax. 16 A
Sensor Supply Voltage (Nominal)24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)18 V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (Sensor Supply)LED green
Diagnostic IndicatorLED red
Current Carrying Capacity of Connectormax. 16 A
Actuator Supply Voltage (Nominal)24 V DC (SELV/PELV)
Actuator Supply Voltage (Range)18 V DC to 30 V DC
Reverse Polarity ProtectionYes
Status Indicator (Actuator Supply)LED green
Diagnostic IndicatorLED red

Digital Input Channels

Number of Digital Input Channelsup to 8
ConnectionM12, 5-poles, A-coded
Number of Ports4x, X1 to X4
Channel TypeType 3 acc. to IEC 61131-2
Input Wiring2-, 3-, 4-wire
Nominal Voltage24 V DC via US (module power supply)
Nominal Currenttyp. 5 mA
Sensor Current Supplymax. 200mA per port
Sensor TypePNP
Input Voltage Range "0" signal-3 V DC …+5 V DC
Input Voltage Range "1" signal11 V DC … 30 V DC
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Status Indicator (Inputs)LED white or yellow per channel
Diagnostic IndicatorLED red per port

Digital Output Channels

Number of Digital Output Channelsup to 8
ConnectionM12, 5-poles, A-coded
Number of Ports4x, X5 to X8
Channel Typep-switching
Output Wiring2-wire
Nominal Voltage24 V DC via UL
Output Current per Channelmax. 2 A
Output Current per Modulemax. 16 A (for UL compliance: max 9A)
Galvanically IsolatedNo
Protective CircuitElectronicaly: Overload protection, short-circuit protection
Overload BehaviorAuto off and on switching / Manual restart
Status Indicator (Outputs)LED white or yellow per channel
Diagnostic IdicatorLED red per channel

Electrical Isolation

US (System Supply Voltage) / FE500 V DC
UL / FE500 V DC
Bus connection / FE2000 V DC

EMC Conformance

EMC Directive2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic FieldCriterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)Criterion B, 2 kV
EN 61000-4-5 Surge VoltageCriterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunityCriterion A; Test voltage 10 V
EN 55032 Radio Interference PropertiesClass A

Safety & Environmental Compliance

CEYes
RoHS CompliantYes
China RoHS-CompliantYes

Approvals

ULcULus Listed, UL 61010-1
CSAYes, via UL
PNOYes
ODVAYes
ETGYes

Notes

Protection Degree / IP Rating Note*only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
System Power Supply Connection Note*do not connect / disconnect under voltage!
Update and RevisionRevision Number: 0.22 Revision Date: 07-20-2023

Documentation

Product Bulletins

Case Studies

Blogs

Technical Information

Reference Manuals

Product Certifications

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Item Description
Variant_Options 935708001:
935708001|0980 XSL 3923-121-007D-01F
View AllClose