UL Instrumentation, 50 Pair 18AWG (7x26) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR
Specifications
Specifications
Product Overview
Suitable Applications | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 50 | 18 AWG | 7x26 | BC - Bare Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Pair(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.021 in (0.53 mm) | 0.088 in (2.2 mm) | Black, White Numbered |
Inner Shield
Element | Shield Type | Material | Coverage | Drainwire Type | Notes |
---|
Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC | Extra polyester tape for isolation |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 18 AWG (7x26) TC |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.085 in (2.2 mm) | 1.526 in (38.76 mm) | Yes |
Overall Cable Diameter (Nominal) | 1.526 in (38.76 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR |
---|
Pair(s) | 5.86 Ohm/1000ft (19.2 Ohm/km) |
Voltage
UL Voltage Rating |
---|
600 V (TC), 150 V (NPLF) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
90°C Dry, 75°C Wet | -30C to 90C Dry, 75C wet |
Bend Radius
Stationary Min. | Installation Min. |
---|
15.3 in (389 mm) | 15.3 in (389 mm) |
Max. Pull Tension | 2962 lbs (1344 kg) |
---|
Bulk Cable Weight | 1226.3 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
---|
Flammability / Reaction to Fire | UL1685 (FT4 Loading), FT4, 1202 |
---|
NEC / UL Compliance | Article 336, Article 760, NPLF, TC |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.225 Revision Date: 04-14-2023 |
---|