Belden

1051A - Inst, 12 Pr #18 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet

(No reviews yet) Write a Review
SKU:
1051A
Shipping:
Calculated at Checkout
$0.00

Description

UL Instrumentation, 12 Pair 18AWG (7x26) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

Specifications

Specifications

Product Overview

Suitable ApplicationsIndustrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Pair(s)1218 AWG7x26BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Pair(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.088 in (2.2 mm)Black, White Numbered

Inner Shield

ElementShield TypeMaterialCoverageDrainwire TypeNotes
Pair(s)TapeBi-Laminate (Alum+Poly)100%20 AWG (7x28) TCExtra polyester tape for isolation

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%18 AWG (7x26) TC

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.064 in (1.6 mm)0.785 in (19.9 mm)Yes
Overall Cable Diameter (Nominal)0.785 in (19.9 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCR
Pair(s)5.86 Ohm/1000ft (19.2 Ohm/km)

Voltage

UL Voltage Rating
600 V (TC-ER), 150 V (NPLF)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-30C to 90C Dry, 75C wet

Bend Radius

Stationary Min.Installation Min.
9.4 in (240 mm)9.4 in (240 mm)
Max. Pull Tension728 lbs (330 kg)
Bulk Cable Weight331 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL1685 (FT4 Loading), FT4, 1202
NEC / UL ComplianceArticle 336, Article 760, NPLF, TC-ER
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.404 Revision Date: 04-14-2023

Documentation

Catalogs

Compliance Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 1051A 0105000:
1051A 0105000|Black|Reel|5,000 ft|612825105398
View AllClose