Belden

1095A - Inst, 12 Tri #18 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 75C Wet

(No reviews yet) Write a Review
SKU:
1095A
Shipping:
Calculated at Checkout
$0.00

Description

UL Instrumentation, 12 Triad 18AWG (7x26) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR

Specifications

Specifications

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Triad(s)1218 AWG7x26BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Triad(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.022 in (0.56 mm)0.088 in (2.2 mm)ICEA Chart E1

Inner Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%20 AWG (7x28) TC

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%18 AWG (7x26) TC

Outer Jacket

SeparatorMaterialNom. ThicknessNom. DiameterRipcord
Polyester TapePVC - Polyvinyl Chloride0.084 in (2.1 mm)0.962 inYes
Overall Cable Diameter (Nominal)0.962 in

Electrical Characteristics

Electricals

Nom. Conductor DCRNom. Inner Shield DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-ShieldNom. Capacitance Cond-to-Other (Conds + Shield)Max. Current
6.7 Ohm/1000ft7.11 Ohm/1000ft (23.3 Ohm/km)37 pF/ft (120 pF/m)43 pF/ft (140 pF/m)30 pF/ft (98 pF/m)6 Amps per Conductor at 30ºC

Voltage

UL Voltage Rating
600 V (TC-ER), 150 V (NPLF)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 75°C Wet-20°C To +90°C Dry, +75°C Wet

Bend Radius

Stationary Min.Installation Min.
3.848 in (97.74 mm)4.81 in
Max. Pull Tension997 lbs (452 kg)
Bulk Cable Weight503 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
Flammability / Reaction to FireUL1685 UL Loading, FT4, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, Article 760
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesTriad groups are numbered for ease of identification. Alternate color coding available upon request.

History

Update and RevisionRevision Number: 0.426 Revision Date: 12-20-2022

Documentation

Catalogs

Compliance Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 1095A 0102500:
1095A 0102500|Black|Reel|2,500 ft|612825106401
Variant_Options 1095A 0105000:
1095A 0105000|Black|Reel|5,000 ft|612825106418
View AllClose