UL Instrumentation, 4 Triad 16AWG (7x24) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

Specifications

Specifications

Product Overview

Suitable ApplicationsIndustrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …),RTD, control circuits, distributed control system (DCS),programmable logic controller (PLC),  Solenoids, Valves, actuators, positioners

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Triad(s)416 AWG7x24BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Triad(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.022 in (0.56 mm)0.101 in (2.57 mm)ICEA Chart E1

Inner Shield

ElementShield TypeMaterialCoverageDrainwire TypeNotes
Triad(s)TapeBi-Laminate (Alum+Poly)100%18 AWG (7x26) TCeach triad

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%16 AWG (7x24) TC

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.064 in (1.6 mm)0.646 in (16.4 mm)Yes
Overall Cable Diameter (Nominal)0.646 in (16.4 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Inner Shield DCRMax. Current
Triad(s)4.36 Ohm/1000ft4.99 Ohm/1000ft (16.4 Ohm/km)9 Amps per conductor @ 30°C

Voltage

UL Voltage Rating
600 V (TC-ER), 150 V (NPLF)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-30°C to 90°C Dry/Wet

Bend Radius

Stationary Min.Installation Min.
7.8 in (200 mm)7.8 in (200 mm)
Max. Pull Tension487 lbs (221 kg)
Bulk Cable Weight245 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to FireUL 1685 FT4 Loading, FT4, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, Article 760, NPLF, TC-ER
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.551 Revision Date: 04-14-2023

Documentation

Catalogs

Compliance Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 1097A 0105000:
1097A 0105000|Black|Reel|5,000 ft|612825106593
View AllClose