10GXW (0.250" Diameter) Category 6A Premise Horizontal Cable (500MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP, Flamarrest® PVC-LS Jacket
Specifications
Specifications
Product Overview
Suitable Applications | Premise Horizontal Cable, Ethernet 10GBASE-T, Wi-Fi 6, Wi-Fi 5, In-Building Wireless, In-Building Small Cells, Mobile RAN, PoE++, PoE+, PoE, HDBaseT |
---|
Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
---|
Construction Details
Conductor
Size | Stranding | Material | Number of Pairs |
---|
23 AWG | Solid | BC - Bare Copper | 4 |
Insulation
Material | Color Code |
---|
FEP - Fluorinated Ethylene Propylene | White & Blue, White & Orange, White & Green, White & Brown |
Outer Jacket
Separator | Material | Material Trade Name | Nom. Diameter | Ripcord |
---|
Center Member (Patented X-Spline®), EquiBlock™ Barrier Technology | PVC - Polyvinyl Chloride | Flamarrest® | 0.250 in (6.35 mm) | Yes |
Overall Cable Diameter (Nominal) | 0.250 in (6.35 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|
82 Ohm/km (25 Ohm/1000ft) | 45 pF/100m |
Delay
Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|
537.6 ns/100m | 45 ns/100m | 69% |
Voltage
UL Voltage Rating |
---|
300 V (CMP) |
Mechanical Characteristics
Temperature
UL Temperature | Operating | Installation | Storage |
---|
105°C | -20°C To +75°C | 0°C To +50°C | -20°C To +75°C |
Bend Radius
Stationary Min. |
---|
1 in (25 mm) |
Max. Pull Tension | 25 lbs (11 kg) |
---|
Bulk Cable Weight | 34 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Plenum, Indoor |
---|
Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), FT6 |
---|
NEC / UL Compliance | Article 800 |
---|
CEC / C(UL) Compliance | CMP |
---|
ICEA Compliance | S-116-732 |
---|
IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
---|
NEMA Compliance | ANSI/NEMA WC-66 |
---|
Data Category | Category 6A |
---|
TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
---|
ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. |
---|
History
Update and Revision | Revision Number: 0.114 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Termination Tools
Compliance Documentation
Data Sheets