10GXW (0.250" Diameter) Category 6A Premise Horizontal Cable (500MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP, Flamarrest® PVC-LS Jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Premise Horizontal Cable, Ethernet 10GBASE-T, Wi-Fi 6, Wi-Fi 5, In-Building Wireless, In-Building Small Cells, Mobile RAN, PoE++, PoE+, PoE, HDBaseT |
|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
|---|
Construction Details
Conductor
| Size | Stranding | Material | Number of Pairs |
|---|
| 23 AWG | Solid | BC - Bare Copper | 4 |
Insulation
| Material | Color Code |
|---|
| FEP - Fluorinated Ethylene Propylene | White & Blue, White & Orange, White & Green, White & Brown |
Outer Jacket
| Separator | Material | Material Trade Name | Nom. Diameter | Ripcord |
|---|
| Center Member (Patented X-Spline®), EquiBlock™ Barrier Technology | PVC - Polyvinyl Chloride | Flamarrest® | 0.250 in (6.35 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.250 in (6.35 mm) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Capacitance Unbalance |
|---|
| 82 Ohm/km (25 Ohm/1000ft) | 45 pF/100m |
Delay
| Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
|---|
| 537.6 ns/100m | 45 ns/100m | 69% |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating | Installation | Storage |
|---|
| 105°C | -20°C To +75°C | 0°C To +50°C | -20°C To +75°C |
Bend Radius
| Stationary Min. |
|---|
| 1 in (25 mm) |
| Max. Pull Tension | 25 lbs (11 kg) |
|---|
| Bulk Cable Weight | 34 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Plenum, Indoor |
|---|
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), FT6 |
|---|
| NEC / UL Compliance | Article 800 |
|---|
| CEC / C(UL) Compliance | CMP |
|---|
| ICEA Compliance | S-116-732 |
|---|
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
|---|
| NEMA Compliance | ANSI/NEMA WC-66 |
|---|
| Data Category | Category 6A |
|---|
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
|---|
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. |
|---|
History
| Update and Revision | Revision Number: 0.114 Revision Date: 01-20-2023 |
|---|