10GXW Category 6A Enhanced Premise Horizontal Cable (500MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, F/UTP - Foil Shielded, Riser-CMR, PVC Jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, Surveillance, HDBaseT, PoE++, PoE+, PoE, Noisy Environments |
|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
|---|
Construction Details
Conductor
| Size | Stranding | Material | Number of Pairs |
|---|
| 23 AWG | Solid | BC - Bare Copper | 4 |
Insulation
| Material | Color Code |
|---|
| PO - Polyolefin | White & Blue, White & Orange, White & Green, White & Brown |
Outer Shield
| Shield Type | Material | Coverage |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Jacket
| Material | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.265 in (6.73 mm) |
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Capacitance Unbalance |
|---|
| 82 Ohm/km (25 Ohm/1000ft) | 45 pF/100m |
Delay
| Max. Delay | Nom. Velocity of Prop. |
|---|
| 537.6 ns/100m | 70% |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMR), 300 V (CL3R) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating | Storage |
|---|
| 90°C | -20°C To +75°C | -20°C To +75°C |
Bend Radius
| Installation Min. |
|---|
| 2.65 in (67.3 mm) |
| Max. Pull Tension | 25 lbs (11 kg) |
|---|
| Bulk Cable Weight | 37 lbs/1000 ft |
|---|
Standards and Compliance
| Environmental Suitability | Riser, Indoor |
|---|
| Flammability / Reaction to Fire | UL 1666 Riser, FT4 |
|---|
| CEC / C(UL) Compliance | CMR |
|---|
| ICEA Compliance | S-116-732 |
|---|
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
|---|
| NEMA Compliance | ANSI/NEMA WC-66 |
|---|
| Data Category | Category 6A |
|---|
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
|---|
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical system. |
|---|
History
| Update and Revision | Revision Number: 0.6 Revision Date: 04-08-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Termination Tools
Data Sheets