10GXW Category 6A Enhanced Premise Horizontal Cable (500MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, F/UTP - Foil Shielded, Riser-CMR, PVC Jacket
Specifications
Specifications
Product Overview
Suitable Applications | Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, Surveillance, HDBaseT, PoE++, PoE+, PoE, Noisy Environments |
---|
Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
---|
Construction Details
Conductor
Size | Stranding | Material | Number of Pairs |
---|
23 AWG | Solid | BC - Bare Copper | 4 |
Insulation
Material | Color Code |
---|
PO - Polyolefin | White & Blue, White & Orange, White & Green, White & Brown |
Outer Shield
Shield Type | Material | Coverage |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.265 in (6.73 mm) |
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|
82 Ohm/km (25 Ohm/1000ft) | 45 pF/100m |
Delay
Max. Delay | Nom. Velocity of Prop. |
---|
537.6 ns/100m | 70% |
Voltage
UL Voltage Rating |
---|
300 V (CMR), 300 V (CL3R) |
Mechanical Characteristics
Temperature
UL Temperature | Operating | Storage |
---|
90°C | -20°C To +75°C | -20°C To +75°C |
Bend Radius
Installation Min. |
---|
2.65 in (67.3 mm) |
Max. Pull Tension | 25 lbs (11 kg) |
---|
Bulk Cable Weight | 37 lbs/1000 ft |
---|
Standards and Compliance
Environmental Suitability | Riser, Indoor |
---|
Flammability / Reaction to Fire | UL 1666 Riser, FT4 |
---|
CEC / C(UL) Compliance | CMR |
---|
ICEA Compliance | S-116-732 |
---|
IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
---|
NEMA Compliance | ANSI/NEMA WC-66 |
---|
Data Category | Category 6A |
---|
TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
---|
ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical system. |
---|
History
Update and Revision | Revision Number: 0.6 Revision Date: 04-08-2022 |
---|
Documentation
Product Bulletins
Catalogs
Termination Tools
Data Sheets