Series 6, 18 AWG solid .040" bare copper-covered steel conductor with Coreguard, gas-injected foam polyethylene insulation, with Coreguard® and flooding compound, Duobond® IV quad shield (60% and 40% coverage), polyethylene jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | CATV, Broadband |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 18 | Solid | BCCS - Bare Copper Covered Steel | 0.04 in | 1 |
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene (Foam) | 0.18 in |
Outer Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] |
|---|
| Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 2 | Aluminum | | 60% |
| Tape | 3 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 4 | Aluminum | | 40% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| PE - Polyethylene | 0.298 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 28 Ohm/1000ft | 4.8 Ohm/1000ft | 4.8 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 16.2 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.097 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
Return Loss
| Frequency [MHz] | Min. Structural Return Loss (SRL) |
|---|
| 5 MHz | 20 dB |
| 1000 MHz | 20 dB |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 5 MHz | 0.67 dB/100ft |
| 55 MHz | 1.60 dB/100ft |
| 211 MHz | 2.87 dB/100ft |
| 270 MHz | 3.24 dB/100ft |
| 300 MHz | 3.43 dB/100ft |
| 350 MHz | 3.72 dB/100ft |
| 400 MHz | 4.00 dB/100ft |
| 450 MHz | 4.26 dB/100ft |
| 550 MHz | 4.71 dB/100ft |
| 750 MHz | 5.59 dB/100ft |
| 870 MHz | 6.00 dB/100ft |
| 1000 MHz | 6.54 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.2 ns/ft | 83% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) |
|---|
| 5 MHz | 0.67 dB/100ft |
| 55 MHz | 1.6 dB/100ft |
| 211 MHz | 2.87 dB/100ft |
| 270 MHz | 3.24 dB/100ft |
| 300 MHz | 3.43 dB/100ft |
| 350 MHz | 3.72 dB/100ft |
| 400 MHz | 4 dB/100ft |
| 450 MHz | 4.26 dB/100ft |
| 550 MHz | 4.71 dB/100ft |
| 750 MHz | 5.59 dB/100ft |
| 870 MHz | 6 dB/100ft |
| 1000 MHz | 6.54 dB/100ft |
Voltage
| Non-UL Voltage Rating |
|---|
| 350 V RMS |
Temperature Range
| Operating Temperature Range | -55°C To +80°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 28 lbs/1000ft |
|---|
| Max. Pull Tension | 162 lbs |
|---|
| Min. Bend Radius/Minor Axis | 3 in |
|---|
Standards
Applicable Environmental and Other Programs
| Environmental Space | Outdoor - Water Exposure |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/96/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | No |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Aerial | Yes - When supported by messenger wire |
|---|
| Suitability - Burial | Yes |
|---|
| Suitability - Hazardous Locations | No |
|---|
| Suitability - Indoor | No |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | No |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
History
| Update and Revision | Revision Number: 0.389 Revision Date: 11-09-2022 |
|---|