Belden

121700R - DataTuff® 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt, CMG CM -40C

(No reviews yet) Write a Review
SKU:
121700R
Shipping:
Calculated at Checkout
$0.00

Description

Industrial Ethernet Cat 5e, 4 Bonded-Pair 24AWG (Solid) Bare Copper, PO Insulation, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, CMG CM -40C

Specifications

Specifications

Product Overview

Suitable Applicationsharsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force,, lower temperature
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor

ElementSizeStrandingMaterialNumber of Element
Pair(s)24 AWGSolidBC - Bare Copper4

Insulation

MaterialColor Code
PO - PolyolefinWhite/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Bonded-PairYes

Inner Jacket

MaterialNom. DiameterRipcord
PVC - Polyvinyl Chloride0.2 in (5.1 mm)Yes

Armor

Armor Type & MaterialArmor ThicknessDiameter Over Armor
AIA - Aluminum Interlock Armor0.025 in (0.64 mm)0.463 in (11.8 mm)

Outer Jacket

SeparatorMaterialNom. Diameter
Polyester TapePVC - Polyvinyl Chloride0.553 in (14.0 mm)
Overall Cable Diameter (Nominal)0.553 in (14.0 mm)

Electrical Characteristics

Electricals

Max. Conductor DCRMax. Capacitance Unbalance
9 Ohm/1000ft160 pF/100m

Delay

Max. DelayMax. Delay SkewNom. Velocity of Prop.
510 ns/100m25 ns/100m70%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]
12 dB/100m65.365.363.363.363.860.820100 ± 12105 ± 10
44 dB/100m56.356.352.352.351.748.723100 ± 12100 ± 10
85.7 dB/100m51.851.846.146.145.742.724.5100 ± 12100 ± 10
106.4 dB/100m50.350.343.943.943.840.825100 ± 12100 ± 10
168.1 dB/100m47.347.339.139.139.736.725100 ± 12100 ± 10
209.2 dB/100m45.845.835.235.237.734.725100 ± 12100 ± 10
2510.3 dB/100m44.344.334.134.135.832.824.3100 ± 15100 ± 10
31.2511.6 dB/100m42.942.931.331.333.930.923.6100 ± 15100 ± 10
62.516.8 dB/100m38.438.421.621.627.824.821.5100 ± 15100 ± 10
10021.7 dB/100m35.335.317.117.123.820.820.1100 ± 15
15527.7 dB/100m32.532.54.74.719.916.919100 ± 18
20032 dB/100m30.830.83317.714.719100 ± 20
25036.4 dB/100m29.329.30015.812.818100 ± 20
30040.5 dB/100m28.228.20014.211.218100 ± 20
31041.3 dB/100m27.927.913.910.918100 ± 20
35044.3 dB/100m27.227.212.99.917100 ± 22

Voltage

UL Voltage Rating
300 V (CM), 300 V (CMG)

Mechanical Characteristics

Temperature

UL TemperatureOperatingInstallationStorage
60°C-40°C To +60°C-40°C To +75°C-40°C To +60°C

Bend Radius

Stationary Min.
6.5 in (170 mm)
Max. Pull Tension40 lbs (18 kg)
Bulk Cable Weight123 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca; CPR UKCA Class: Eca
NEC / UL ComplianceCM
CEC / C(UL) ComplianceCMG, HL
Data CategoryCategory 5e
TIA/EIA ComplianceANSI/TIA-568.2-D Category 5e
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark

Product Notes

NotesUS Patent #'s 5, 606, 151; 5, 734, 126 Operating temperatures are subject to length de-rating. Cable passes -40C Cold Bend per UL 1581. Cable passes -40C cold impact.

History

Update and RevisionRevision Number: 0.237 Revision Date: 01-04-2023
View AllClose