Audio Snake Cable, 12-22 AWG tinned copper pairs, Datalene® insulation, individually shielded with Beldfoil® bonded to numbered/color-coded PVC jackets so both strip simulteaneously, flexible PVC jacket
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Pairs | 
|---|
| 22 | 7x30 | TC - Tinned Copper | 0.03 in | 12 | 
| Conductor Count | 24 | 
|---|
| Total Number of Pairs | 12 | 
|---|
Insulation
| Material | Material Trade Name | Nominal Diameter | Nominal Wall Thickness | 
|---|
| PE - Polyethylene (Foam) | Datalene® | 0.06 in | 0.015 in | 
Color Chart
| Number | Color | 
|---|
| 1 | Brown | 
| 2 | Red | 
| 3 | Yellow | 
| 4 | Orange | 
| 5 | Green | 
| 6 | Blue | 
| 7 | Purple | 
| 8 | Gray | 
| 9 | White | 
| 10 | Black | 
| 11 | Tan | 
| 12 | Pink | 
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D | 
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.030 in | 22 | 7x30 | 
Inner Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | 
|---|
| PVC - Polyvinyl Chloride | 0.153 in | 0.015 in | 
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord | 
|---|
| PVC - Polyvinyl Chloride | 0.76 in | 0.074 in | Yes | 
Electrical Characteristics
Conductor DCR
| Individual Pair Nominal Shield DCR | Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | 
|---|
| 10.6 Ohm/1000ft | 15 Ohm/1000ft | 15 Ohm/1000ft | 
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield | 
|---|
| 19 pF/ft | 35 pF/ft | 
Inductance
| Nominal Inductance | 
|---|
| 0.2 µH/ft | 
Delay
| Nominal Velocity of Propagation (VP) [%] | 
|---|
| 78% | 
Current
| Max. Recommended Current [A] | 
|---|
| 1.5 Amps per Conductor at 20ºC | 
Voltage
| Non-UL Voltage Rating | Voltage Rating [V] | 
|---|
| 150 V RMS | 300 V RMS | 
| 300 V RMS |  | 
Temperature Range
| Non-UL Temp Rating | 60°C | 
|---|
| Operating Temperature Range | -20°C To +60°C | 
|---|
Mechanical Characteristics
| Bulk Cable Weight | 271 lbs/1000ft | 
|---|
| Max. Pull Tension | 328 lbs | 
|---|
| Min. Bend Radius/Minor Axis | 7.75 in | 
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) | 
|---|
| EU Directive 2000/53/EC (ELV) | Yes | 
|---|
| EU Directive 2003/11/EC (BFR) | Yes | 
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes | 
|---|
| EU Directive 2012/19/EU (WEEE) | Yes | 
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes | 
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) | 
|---|
| EU CE Mark | Yes | 
|---|
| MII Order #39 (China RoHS) | Yes | 
|---|
Suitability
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. | 
|---|
Product Notes
| Notes | Datalene® insulation features include a low dielectric constant and a low dissipation factor for high-speed, low distortion data handling. Physical properties include good crush resistance and light weight. Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. | 
|---|
History
| Update and Revision | Revision Number: 0.351    Revision Date: 12-20-2022 | 
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets