Category 3 Premise Horizontal Cable (16MHz), 2 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Riser-CMR, PVC Jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Ethernet 10BASE-T, Analog Phone, FAX |
|---|
Construction Details
Conductor
| Size | Stranding | Material | Number of Pairs |
|---|
| 24 AWG | Solid | BC - Bare Copper | 2 |
Insulation
| Material | Color Code |
|---|
| PO - Polyolefin | White/Blue Stripe & Blue, White/Orange Stripe & Orange |
Outer Jacket
| Material | Nom. Diameter | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.173 in (4.39 mm) | No |
| Overall Cable Diameter (Nominal) | 0.173 in (4.39 mm) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Capacitance Unbalance |
|---|
| 93.8 Ohm/km (28.6 Ohm/1000ft) | 90 pF/100m |
Delay
| Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
|---|
| 16 MHz | 543 ns/100m | 45 ns/100m | 70% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. SRL (Structural Return Loss) [dB] | Max./Min. Fitted Impedance [Ohm] |
|---|
| 1 | 2.6 dB/100m | 41.0 | 12.0 | 100 ± 15 |
| 4 | 5.6 dB/100m | 32.0 | 12.0 | 100 ± 15 |
| 8 | 8.5 dB/100m | 27.0 | 12.0 | 100 ± 15 |
| 10 | 9.7 dB/100m | 26.0 | 12.0 | 100 ± 15 |
| 16 | 13.1 dB/100m | 23.0 | 10.0 | 100 ± 15 |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMR) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating | Installation | Storage |
|---|
| 75°C | -20°C To +75°C | 0°C To +50°C | -20°C To +75°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 1.0 in (25 mm) | 1.75 in (44.5 mm) |
| Max. Pull Tension | 15 lbs (6.8 kg) |
|---|
| Bulk Cable Weight | 12 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Riser, Indoor, Outdoor, Sunlight Resistance |
|---|
| Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
|---|
| Flammability / Reaction to Fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
|---|
| NEC / UL Compliance | Article 800, CMR |
|---|
| CEC / C(UL) Compliance | CMR |
|---|
| ICEA Compliance | S-90-661 |
|---|
| NEMA Compliance | NEMA WC-63.1 |
|---|
| Data Category | Category 3 |
|---|
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 3 |
|---|
| Third Party Performance Verification | Category 3 |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
| Plenum Number | 1243A2 |
|---|
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage Markings. |
|---|
History
| Update and Revision | Revision Number: 0.549 Revision Date: 01-20-2023 |
|---|
Documentation
Technical Documents
Product Guides
Reference Manuals
Compliance Documentation
Data Sheets