Belden

1229502 - VFD 300% Gnd, 3C+G #12 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#12 TC Drain, PVC Jkt, AIA Armor, Blk PVC Jkt, 600V MC 90C Dry/Wet

(No reviews yet) Write a Review
SKU:
1229502
Shipping:
Calculated at Checkout
$0.00

Description

Belden 300% Ground Flexible VFD, 3 Conductor 12AWG (65x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield w/12AWG Tinned Copper Drain, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, 600V MC 90C Dry/Wet SUN RES DIR BUR CT USE Oil Resistant

Specifications

Specifications

Put-Up TypeReel

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Exposure to rodents, crush or impact forces

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Conductor(s)312 AWG65x30TC - Tinned Copper
Ground112 AWG65x30TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.046 in (1.2 mm)0.187 in (4.75 mm)Black and Numbered
GroundPVC - Polyvinyl Chloride0.046 in (1.2 mm)0.187 in (4.75 mm)Green/Yellow Stripe

Outer Shield

Shield TypeMaterialCoverage
TapeTri-Laminate (Alum+Poly+Alum)100%
BraidTinned Copper (TC)85%

Inner Jacket

MaterialNom. ThicknessNom. Diameter
PVC - Polyvinyl Chloride0.073 in (1.9 mm)0.630 in (16.0 mm)

Armor

Armor Type & Material
AIA - Aluminum Interlock Armor

Outer Jacket

MaterialNom. ThicknessNom. DiameterRipcord
PVC - Polyvinyl Chloride0.050 in (1.3 mm)0.960 in (24.4 mm)Yes
Overall Cable Diameter (Nominal)0.960 in (24.4 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)1.567 Ohm/1000ft (5.141 Ohm/km)45 pF/ft (150 pF/m)81 pF/ft (270 pF/m)41 Ohm55%30 Amps per Conductor at 30ºC

Voltage

UL Voltage Rating
600 V (MC)

Mechanical Characteristics

Temperature

UL TemperatureOperating
90°C Dry, 90°C Wet-25°C To +90°C

Bend Radius

Stationary Min.Installation Min.
11.5 in (292 mm)11.5 in (292 mm)
Max. Pull Tension395 lbs (179 kg)
Bulk Cable Weight457 lbs/1000ft (680 kg/km)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 Vertical Tray, 1202, 383 Vertical Tray Flame Test (70,000 BTU)
NEC / UL ComplianceArticle 336, MC
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.71 Revision Date: 12-20-2022

Documentation

Catalogs

Technical Resources

Videos

Compliance Documentation

Data Sheets