ControlBus™, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, PO Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, CM
Specifications
Specifications
Product Overview
Suitable Applications | Exposure to rodent, crush, or cut through force, harsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
---|
Construction Details
Conductor
Element | Size | Stranding | Nom. Diameter | Material |
---|
Coax(es) | 18 AWG | Solid | 0.0403 in | BCCS - Bare Copper Covered Steel |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
PE - Polyethylene (Foam) | 0.178 in (4.52 mm) | White |
Inner Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.298 in (7.57 mm) |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
2 | Braid | Aluminum | | 60% |
3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
4 | Braid | Aluminum | | 40% |
Armor
Armor Type & Material | Armor Thickness | Diameter Over Armor |
---|
AIA - Aluminum Interlock Armor | 0.025 in (0.64 mm) | 0.501 in (12.7 mm) |
Outer Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.591 in (15.0 mm) |
Overall Cable Diameter (Nominal) | 0.591 in (15.0 mm) |
---|
Electrical Characteristics
Return Loss
Frequency | Min. Structural Return Loss |
---|
5 MHz - 50 MHz | 23 dB |
Attenuation
Frequency | Nom. Attenuation |
---|
1 MHz | 0.35 dB/100ft |
2 MHz | 0.38 dB/100ft |
5 MHz | 0.45 dB/100ft |
10 MHz | 0.59 dB/100ft |
20 MHz | 0.86 dB/100ft |
50 MHz | 1.37 dB/100ft |
100 MHz | 1.97 dB/100ft |
200 MHz | 2.82 dB/100ft |
300 MHz | 3.48 dB/100ft |
400 MHz | 4.04 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
28 Ohm/1000ft (92 Ohm/km) | 3.6 Ohm/1000ft (12 Ohm/km) | 16.2 pF/ft (53.1 pF/m) | 75 Ohm | 82% |
Voltage
Electrical Characteristics Notes | SRL Minimum 23dB (5MHz - 50MHz) |
---|
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
75°C | -40°C To +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
4 in (100 mm) | 2.5 in (64 mm) |
Max. Pull Tension | 200 lbs (91 kg) |
---|
Bulk Cable Weight | 142 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor (Not Riser or Plenum), Indoor, Outdoor, Sunlight Resistance |
---|
Flammability / Reaction to Fire | UL1685 UL Loading, FT4, 1202 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | Article 800, CL2, CM |
---|
CEC / C(UL) Compliance | CMG, HL |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | ControlNet is a ControlNet International trademark. |
---|
History
Update and Revision | Revision Number: 0.268 Revision Date: 05-25-2023 |
---|
Documentation
Catalogs
Technical Resources
Compliance Documentation
Data Sheets