RS-485, 120 Ohm, 1 pair 22AWG (7x30) tinned copper Datalene® insulaton, Overall Foil + 65% Tinned Copper Braid, PVC jacket, Aluminum Interlocking Armor, PVC Jacket, CM, PLTC, SUN RES
Specifications
Specifications
Product Overview
Suitable Applications | exposure to rodent, crush, or cut through force, burial, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 1 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Color Code | Notes |
---|
Pair(s) | PE - Polyethylene (Foam) | 0.029 in (0.74 mm) | White/Blue Stripe & Blue/White Stripe | HDPE |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC |
Braid | Tinned Copper (TC) | 65% | |
Inner Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.281 in (7.14 mm) |
Armor
Armor Type & Material |
---|
AIA - Aluminum Interlock Armor |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.045 in (1.1 mm) | 0.577 in (14.7 mm) |
Overall Cable Diameter (Nominal) | 0.577 in (14.7 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|
Pair(s) | 14.7 Ohm/1000ft (48.2 Ohm/km) | 11 pF/ft (36 pF/m) | 120 Ohm | 78% | 2.7 Amps per Conductor at 25ºC |
Nom. Outer Shield DCR | 2.8 Ohm/1000ft (9.2 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|
Pair(s) | 1 | 0.5 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CM, PLTC) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
60°C | -40°C to +60°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
5.8 in (150 mm) | 5.8 in |
Max. Pull Tension | 200 lbs (91 kg) |
---|
Bulk Cable Weight | 140 lbs/1000ft (210 kg/km) |
---|
Standards and Compliance
Environmental Suitability | Indoor, Sunlight Resistance |
---|
Flammability / Reaction to Fire | UL1685 UL Loading, 1202 |
---|
NEC / UL Compliance | Article 725, Article 800 |
---|
CEC / C(UL) Compliance | CMG HLBCD |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
History
Update and Revision | Revision Number: 0.68 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Solution Guides
Technical Resources
Data Sheets