CAT3 (16MHz), 25-Pair, U/UTP-unshielded, Riser-CMR, Premise Backbone Cable, 24 AWG solid bare copper conductors, semi-rigid PVC insulation, PVC jacket
Specifications
Specifications
Product Overview
Suitable Applications | 802.3 10BaseT, 100BaseT4 |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
24 | Solid | BC - Bare Copper | 25 |
Conductor Count | 50 |
---|
Total Number of Pairs | 25 |
---|
Insulation
Color Chart
Number | Color |
---|
1 | White/Blue Stripe & Blue/White Stripe |
2 | White/Orange Stripe & Orange/White Stripe |
3 | White/Green Stripe & Green/White Stripe |
4 | White/Brown Stripe & Brown/White Stripe |
5 | White/Gray Stripe & Gray/White Stripe |
6 | Red/Blue Stripe & Blue/Red Stripe |
7 | Red/Orange Stripe & Orange/Red Stripe |
8 | Red/Green Stripe & Green/Red Stripe |
9 | Red/Brown Stripe & Brown/Red Stripe |
10 | Red/Gray Stripe & Gray/Red Stripe |
11 | Black/Blue Stripe & Blue/Black Stripe |
12 | Black/Orange Stripe & Orange/Black Stripe |
13 | Black/Green Stripe & Green/Black Stripe |
14 | Black/Brown Stripe & Brown/Black Stripe |
15 | Black/Gray Stripe & Gray/Black Stripe |
16 | Yellow/Blue Stripe & Blue/Yellow Stripe |
17 | Yellow/Orange Stripe & Orange/Yellow Stripe |
18 | Yellow/Green Stripe & Green/Yellow Stripe |
19 | Yellow/Brown Stripe & Brown/Yellow Stripe |
20 | Yellow/Gray Stripe & Gray/Yellow Stripe |
21 | Purple/Blue Stripe & Blue/Purple Stripe |
22 | Purple/Orange Stripe & Orange/Purple Stripe |
23 | Purple/Green Stripe & Green/Purple Stripe |
24 | Purple/Brown Stripe & Brown/Purple Stripe |
25 | Purple/Gray Stripe & Gray/Purple Stripe |
Outer Jacket
Material | Nominal Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.399 in | No |
Electrical Characteristics
Conductor DCR
Max. Conductor DCR | Max. DCR Unbalance |
---|
93.8 Ohm/km | 5 % |
Capacitance
Max. Capacitance Unbalance | Nom.Mutual Capacitance |
---|
330 pF/100m | 15 pF/ft |
Delay
Frequency [MHz] | Max. Delay | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
16 MHz | 543 ns/100m | 1.5 ns/ft | 70% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. PSNEXT [dB] | Min. SRL (Structural Return Loss) | Max./Min. Fitted Impedance |
---|
1 MHz | 2.6 dB/100m | 41.0 dB | 12.0 dB | 100 ± 15 Ohm |
4 MHz | 5.6 dB/100m | 32.0 dB | 12.0 dB | 100 ± 15 Ohm |
8 MHz | 8.5 dB/100m | 27.0 dB | 12.0 dB | 100 ± 15 Ohm |
10 MHz | 9.7 dB/100m | 26.0 dB | 12.0 dB | 100 ± 15 Ohm |
16 MHz | 13.1 dB/100m | 23.0 dB | 10.0 dB | 100 ± 15 Ohm |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
Installation Temperature Range | 0°C To +50°C |
---|
UL Temp Rating | 60°C |
---|
Storage Temperature Range | -20°C To +60°C |
---|
Operating Temperature Range | -20°C To +60°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 90 lbs/1000ft |
---|
Max. Pull Tension | 150 lbs |
---|
Min. Bend Radius During Installation | 2.75 in |
---|
Min. Bend Radius/Minor Axis | 2.25 in |
---|
Standards
NEC/(UL) Compliance | CMR |
---|
CEC/C(UL) Compliance | CMR |
---|
CPR Euroclass | Eca |
---|
Data Category | Category 3 |
---|
ANSI Compliance | S-90-661-2012 Category 3, ANSI/NEMA WC-63.1 Category 3 |
---|
TIA/EIA Compliance | ANSI/TIA-568-C.2 Category 3 |
---|
IEEE Compliance | 802.3 10BaseT, 100BaseT4 |
---|
Third Party Performance Verification | Category 3 |
---|
Applicable Environmental and Other Programs
Environmental Space | Riser |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2002/96/EC (WEEE) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
EU CE Mark | Yes |
---|
EU REACH SVHC Compliance (yyyy-mm-dd) | 2017-07-10 |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Aerial | No |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Non-Halogenated | No |
---|
Suitability - Oil Resistance | No |
---|
Suitability - Outdoor | No |
---|
Suitability - Sunlight Resistance | No |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL 1666 Riser |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum