CAT3, 4-Pair, U/UTP-unshielded, Plenum-CMP, Premise Horizontal cable, 24 AWG solid bare copper conductors, LS-PVC insulation, LS-PVC jacket
Specifications
Specifications
Product Overview
Suitable Applications | 802.3 10BaseT, 100BaseT4 |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
24 | Solid | BC - Bare Copper | 4 |
Conductor Count | 8 |
---|
Total Number of Pairs | 4 |
---|
Insulation
Material |
---|
PVC - Polyvinyl Chloride |
Color Chart
Number | Color |
---|
1 | White/Blue Stripe & Blue |
2 | White/Orange Stripe & Orange |
3 | White/Green Stripe & Green |
4 | White/Brown Stripe & Brown |
Outer Jacket
Material | Material Trade Name | Nominal Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | Flamarrest® | 0.157 in | No |
Electrical Characteristics
Conductor DCR
Max. Conductor DCR | Max. DCR Unbalance |
---|
93.8 Ohm/km | 5 % |
Capacitance
Max. Capacitance Unbalance | Nom.Mutual Capacitance |
---|
330 pF/100m | 19 pF/ft |
Delay
Frequency [MHz] | Max. Delay | Max. Delay Skew | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
100 MHz | 537.6 ns/100m | 45 ns/100m | 1.5 ns/ft | 61% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. SRL (Structural Return Loss) | Max./Min. Fitted Impedance |
---|
1 MHz | 2.6 dB/100m | 41.0 dB | 12.0 dB | 100 ± 15 Ohm |
4 MHz | 5.6 dB/100m | 32.0 dB | 12.0 dB | 100 ± 15 Ohm |
8 MHz | 8.5 dB/100m | 27.0 dB | 12.0 dB | 100 ± 15 Ohm |
10 MHz | 9.7 dB/100m | 26.0 dB | 12.0 dB | 100 ± 15 Ohm |
16 MHz | 13.1 dB/100m | 23.0 dB | 10.0 dB | 100 ± 15 Ohm |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
Installation Temperature Range | 0°C To +50°C |
---|
UL Temp Rating | 60°C |
---|
Storage Temperature Range | -20°C To +60°C |
---|
Operating Temperature Range | -20°C To +60°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 18 lbs/1000ft |
---|
Max. Pull Tension | 25 lbs |
---|
Min. Bend Radius During Installation | 4.75 in |
---|
Min. Bend Radius/Minor Axis | 2.25 in |
---|
Standards
NEC/(UL) Compliance | CMP |
---|
CEC/C(UL) Compliance | CMP |
---|
Data Category | Category 3 |
---|
ANSI Compliance | S-90-661-2012 Category 3, ANSI/NEMA WC-63.1 Category 3 |
---|
TIA/EIA Compliance | ANSI/TIA-568-C.2 Category 3 |
---|
Third Party Performance Verification | Category 3 |
---|
Applicable Environmental and Other Programs
Environmental Space | Plenum |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2002/96/EC (WEEE) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
EU CE Mark | Yes |
---|
EU REACH SVHC Compliance (yyyy-mm-dd) | 2017-07-10 |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Aerial | No |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Non-Halogenated | No |
---|
Suitability - Oil Resistance | No |
---|
Suitability - Outdoor | No |
---|
Suitability - Sunlight Resistance | No |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | NFPA 262 Plenum (UL 910) |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage Markings. |
---|
History
Update and Revision | Revision Number: 0.432 Revision Date: 12-20-2022 |
---|
Documentation
Technical Documents
Product Guides
Reference Manuals
Data Sheets