CAT3, 4-Pair, U/UTP-unshielded, Plenum-CMP, Premise Horizontal cable, 24 AWG solid bare copper conductors, LS-PVC insulation, LS-PVC jacket
Specifications
Specifications
Product Overview
| Suitable Applications | 802.3 10BaseT, 100BaseT4 | 
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs | 
|---|
| 24 | Solid | BC - Bare Copper | 4 | 
| Conductor Count | 8 | 
|---|
| Total Number of Pairs | 4 | 
|---|
Insulation
| Material | 
|---|
| PVC - Polyvinyl Chloride | 
Color Chart
| Number | Color | 
|---|
| 1 | White/Blue Stripe & Blue | 
| 2 | White/Orange Stripe & Orange | 
| 3 | White/Green Stripe & Green | 
| 4 | White/Brown Stripe & Brown | 
Outer Jacket
| Material | Material Trade Name | Nominal Diameter | Ripcord | 
|---|
| PVC - Polyvinyl Chloride | Flamarrest® | 0.157 in | No | 
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR | Max. DCR Unbalance | 
|---|
| 93.8 Ohm/km | 5 % | 
Capacitance
| Max. Capacitance Unbalance | Nom.Mutual Capacitance | 
|---|
| 330 pF/100m | 19 pF/ft | 
Delay
| Frequency [MHz] | Max. Delay | Max. Delay Skew | Nominal Delay | Nominal Velocity of Propagation (VP) [%] | 
|---|
| 100 MHz | 537.6 ns/100m | 45 ns/100m | 1.5 ns/ft | 61% | 
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. SRL (Structural Return Loss) | Max./Min. Fitted Impedance | 
|---|
| 1 MHz | 2.6 dB/100m | 41.0 dB | 12.0 dB | 100 ± 15 Ohm | 
| 4 MHz | 5.6 dB/100m | 32.0 dB | 12.0 dB | 100 ± 15 Ohm | 
| 8 MHz | 8.5 dB/100m | 27.0 dB | 12.0 dB | 100 ± 15 Ohm | 
| 10 MHz | 9.7 dB/100m | 26.0 dB | 12.0 dB | 100 ± 15 Ohm | 
| 16 MHz | 13.1 dB/100m | 23.0 dB | 10.0 dB | 100 ± 15 Ohm | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V RMS | 
Temperature Range
| Installation Temperature Range | 0°C To +50°C | 
|---|
| UL Temp Rating | 60°C | 
|---|
| Storage Temperature Range | -20°C To +60°C | 
|---|
| Operating Temperature Range | -20°C To +60°C | 
|---|
Mechanical Characteristics
| Bulk Cable Weight | 18 lbs/1000ft | 
|---|
| Max. Pull Tension | 25 lbs | 
|---|
| Min. Bend Radius During Installation | 4.75 in | 
|---|
| Min. Bend Radius/Minor Axis | 2.25 in | 
|---|
Standards
| NEC/(UL) Compliance | CMP | 
|---|
| CEC/C(UL) Compliance | CMP | 
|---|
| Data Category | Category 3 | 
|---|
| ANSI Compliance | S-90-661-2012 Category 3, ANSI/NEMA WC-63.1 Category 3 | 
|---|
| TIA/EIA Compliance | ANSI/TIA-568-C.2 Category 3 | 
|---|
| Third Party Performance Verification | Category 3 | 
|---|
Applicable Environmental and Other Programs
| Environmental Space | Plenum | 
|---|
| EU Directive 2000/53/EC (ELV) | Yes | 
|---|
| EU Directive 2002/96/EC (WEEE) | Yes | 
|---|
| EU Directive 2003/11/EC (BFR) | Yes | 
|---|
| EU Directive 2003/96/EC (BFR) | Yes | 
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes | 
|---|
| EU Directive 2012/19/EU (WEEE) | Yes | 
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes | 
|---|
| EU Directive Compliance | Yes | 
|---|
| EU CE Mark | Yes | 
|---|
| EU REACH SVHC Compliance (yyyy-mm-dd) | 2017-07-10 | 
|---|
| MII Order #39 (China RoHS) | Yes | 
|---|
Suitability
| Suitability - Aerial | No | 
|---|
| Suitability - Burial | No | 
|---|
| Suitability - Hazardous Locations | No | 
|---|
| Suitability - Indoor | Yes | 
|---|
| Suitability - Non-Halogenated | No | 
|---|
| Suitability - Oil Resistance | No | 
|---|
| Suitability - Outdoor | No | 
|---|
| Suitability - Sunlight Resistance | No | 
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 Plenum (UL 910) | 
|---|
| UL voltage rating | 300 V RMS | 
|---|
Plenum/Non-Plenum
Related Part Numbers
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage Markings. | 
|---|
History
| Update and Revision | Revision Number: 0.432    Revision Date: 12-20-2022 | 
|---|
Documentation
Technical Documents
Product Guides
Reference Manuals
Data Sheets