DeviceBus® for ODVA DeviceNet™, 2 Pair 15+18AWG (19x27+19x30) Tinned Copper, PVC-NYL + FEP Insulation, Individual Beldfoil® & OA Tinned Copper Braid(65%) Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, 600V
Specifications
Specifications
Product Overview
| Suitable Applications | exposure to rodent, crush, or cut through force, harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc. |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Power Pair(s) | 1 | 15 AWG | 19x27 | TC - Tinned Copper |
| Data Pair(s) | 1 | 18 AWG | 19x30 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Color Code |
|---|
| Power Pair(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.026 in (0.66 mm) | Red & Black |
| Data Pair(s) | FEP - Fluorinated Ethylene Propylene (Foam) | 0.050 in (1.3 mm) | Blue & White |
Inner Shield
| Element | Shield Type | Material | Coverage |
|---|
| Power Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% |
| Data Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Braid | Tinned Copper (TC) | 65% | 18 AWG (19x30) TC |
Inner Jacket
| Material | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.460 in (11.7 mm) |
Armor
| Armor Type & Material |
|---|
| AIA - Aluminum Interlock Armor |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.050 in (1.3 mm) | 0.763 in (19.4 mm) |
| Overall Cable Diameter (Nominal) | 0.763 in (19.4 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|
| Power Pair(s) | 3.6 Ohm/1000ft (12 Ohm/km) | | | | 8 Amps per Conductor at 25ºC |
| Data Pair(s) | 6.9 Ohm/1000ft (23 Ohm/km) | 12 pF/ft (39 pF/m) | 120 Ohm | 75% | |
| Nom. Outer Shield DCR | 1.8 Ohm/1000ft (5.9 Ohm/km) |
|---|
High Frequency
| Element | Frequency [MHz] | Max. Insertion Loss (Attenuation) | Max./Min. Input Impedance (unFitted) [Ohm] |
|---|
| Data Pair(s) | 0.125 | 0.13 dB/100ft | 120 |
| 0.5 | 0.25 dB/100ft | |
| 1 | 0.40 dB/100ft | |
Voltage
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 75°C Dry | -20°C to +75°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 7.6 in (190 mm) | 7.6 in (190 mm) |
| Max. Pull Tension | 190 lbs (86 kg) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance |
|---|
| Other Standard Compliance(s) | ODVA Class 1 Thick |
|---|
History
| Update and Revision | Revision Number: 0.57 Revision Date: 05-05-2023 |
|---|