Belden

127953A - DataTuff® Cat 6, (4 pr) 24 AWG Solid BC, PP/PVC/Alum Armor/PVC, EtherNet/IP, Foil Shld, CMR, CMX Outdoor, 600V AWM

(No reviews yet) Write a Review
SKU:
127953A
Shipping:
Calculated at Checkout
$0.00

Description

Four Cat 6 24 AWG Bonded-Pairs solid bare copper conductors, polypropylene insulation, FRPE spline center member, inner PVC jacket, overall Beldfoil® Shield (100% coverage), industrial grade oil- and UV-resistant PVC outer jacket

Specifications

Specifications

Product Overview

Suitable ApplicationsArmored Ethernet applications, In Cable tray, in cabinet with high volt devices, such as motor control center, mining, outdoor, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force,

Construction Details

Conductor

ElementSizeStrandingMaterialNumber of Element
Pair(s)24 AWGSolidBC - Bare Copper4

Insulation

MaterialColor Code
PO - PolyolefinWhite/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Bonded-PairYes

Inner Jacket

MaterialNom. DiameterRipcord
PVC - Polyvinyl Chloride0.254 in (6.45 mm)Yes

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%24 AWG (7x32) TC

Armor

Armor Type & MaterialArmor ThicknessDiameter Over Armor
AIA - Aluminum Interlock Armor0.025 in (0.64 mm)0.595 in (15.1 mm)

Outer Jacket

SeparatorMaterialNom. Diameter
Polyester TapePVC - Polyvinyl Chloride0.695 in (17.7 mm)
Overall Cable Diameter (Nominal)0.695 in (17.7 mm)

Electrical Characteristics

Electricals

Max. Conductor DCRMax. Capacitance Unbalance
82 Ohm/km (25 Ohm/1000ft)330 pF/ft

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]
12.0 dB/100m74.372.372.370.367.864.821100 ± 15100 ± 15
43.8 dB/100m65.363.361.559.555.852.724100 ± 15100 ± 15
85.3 dB/100m60.858.855.453.449.746.725.5100 ± 15100 ± 15
106 dB/100m59.357.353.351.347.844.826100 ± 15100 ± 15
167.6 dB/100m56.254.348.746.743.740.726100 ± 15100 ± 15
208.5 dB/100m54.852.846.344.341.838.826100 ± 15100 ± 15
259.5 dB/100m53.351.343.841.839.836.825.3100 ± 15100 ± 15
31.2510.7 dB/100m51.949.941.239.237.934.924.6100 ± 15100 ± 15
62.515.4 dB/100m47.445.4323031.928.922.5100 ± 15100 ± 15
10019.8 dB/100m44.342.324.522.527.824.821.1100 ± 15
15525.2 dB/100m41.539.516.314.323.920.919.8100 ± 22
20029.0 dB/100m39.837.810.88.821.818.819100 ± 22
25032.8 dB/100m38.336.35.53.519.816.818.3100 ± 32

Voltage

UL Voltage Rating
300 V (CMR), 300 V (CMX)

Mechanical Characteristics

Temperature

UL TemperatureOperatingStorage
60°C-20°C to +60°C-20°C to +60°C
Max. Pull Tension200 lbs (91 kg)
Bulk Cable Weight164 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Indoor, Sunlight Resistance
Flammability / Reaction to FireUL 1666 Riser, FT4
NEC / UL ComplianceCMR-CMX
CEC / C(UL) ComplianceCMG, HL
Data CategoryCategory 6
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6
ISO/IEC ComplianceISO/IEC 11801 Cat 6

History

Update and RevisionRevision Number: 0.116 Revision Date: 01-04-2023
View AllClose