Coax RG59, 23AWG (Solid) Bare Copper Covered Steel 40% Conductivity, PO Insulation, Overall Bare Copper Braid(95%) Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, CMG
Specifications
Specifications
Product Overview
Suitable Applications | harsh environment, IIoT, factory or process automation, video, audio, data communication, etc. |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
---|
23 | Solid | BCCS - Bare Copper Covered Steel | 0.023 in | 1 |
Insulation
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PE - Polyethylene | 0.146 in | 0.062 in |
Inner Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.24 in | 0.033 in |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.520 in | 0.045 in |
Construction and Dimensions
Armor
Type of Armor | Material | Thickness of Armoring Tape | Diameter over Armoring |
---|
Interlocked Aluminum | Aluminum | 0.022 in | 0.430 in |
Electrical Characteristics
Capacitance
Nom. Capacitance Conductor to Other Conductor to Shield |
---|
20.5 pF/ft |
Inductance
Nominal Inductance |
---|
0.131 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.6 dB/100ft |
10 MHz | 1.1 dB/100ft |
50 MHz | 2.4 dB/100ft |
100 MHz | 3.4 dB/100ft |
200 MHz | 4.9 dB/100ft |
400 MHz | 7.0 dB/100ft |
700 MHz | 9.7 dB/100ft |
900 MHz | 11.1 dB/100ft |
1000 MHz | 12.0 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.54 ns/ft | 66% |
High Frequency
Max./Min. Input Impedance (unFitted) |
---|
75 |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
UL Temp Rating | 75°C |
---|
Operating Temperature Range | -40°C To +75°C |
---|
Mechanical Characteristics
UV Resistance | Yes |
---|
Bulk Cable Weight | 138 lbs/1000ft |
---|
Min. Bend Radius/Minor Axis | 5.25 in |
---|
Standards
NEC Articles | Article 800 |
---|
NEC/(UL) Compliance | CM |
---|
CEC/C(UL) Compliance | CMG |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
Suitability
Suitability - Hazardous Locations | Yes |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL 1685 UL loading |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.174 Revision Date: 07-19-2023 |
---|
Documentation
Product Bulletins
Catalogs
Tools
Data Sheets