RS-485, 2 Pair 24AWG (7x32) Tinned Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, CM
Specifications
Specifications
Product Overview
Suitable Applications | exposure to rodent, crush, or cut through force, burial, POS, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 2 | 24 AWG | 7x32 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Color Code |
---|
Pair(s) | PE - Polyethylene | 0.022 in (0.56 mm) | White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
Braid | Tinned Copper (TC) | 90% | |
Inner Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.340 in (8.64 mm) |
Armor
Armor Type & Material |
---|
AIA - Aluminum Interlock Armor |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.045 in (1.1 mm) | 0.620 in (15.7 mm) |
Overall Cable Diameter (Nominal) | 0.620 in (15.7 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|
Pair(s) | 24 Ohm/1000ft (79 Ohm/km) | 12.8 pF/ft (42.0 pF/m) | 23 pF/ft | 120 Ohm | 66% | 2.1 Amps per Conductor at 25ºC |
Nom. Outer Shield DCR | 2.2 Ohm/1000ft (7.2 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|
Pair(s) | 1 | 0.6 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CM) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
80°C | -30°C to +80°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
6.2 in (160 mm) | 6.2 in |
Max. Pull Tension | 200 lbs (91 kg) |
---|
Bulk Cable Weight | 162 lbs/1000ft (241 kg/km) |
---|
Standards and Compliance
Environmental Suitability | Indoor, Sunlight Resistance |
---|
Flammability / Reaction to Fire | IEC 60332-1-2 |
---|
NEC / UL Compliance | Article 800, CM |
---|
CEC / C(UL) Compliance | CMG |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.218 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets