Composite Shipboard, 18 AWG Coax BC, BC Braid Shield 95% coverage, FPE insulation for video and 1 PR 18 AWG BC, stranded (7x26), PP insulation for power, overall CMG-LS rating, LSZH jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | Surveillance, CCTV Camera, PTZ (Pan-Tilt-Zoom), Shipboard, Low Smoke |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Conductors | No. of Coax |
|---|
| 18 | Solid | BC - Bare Copper | 0.04 in | | 1 |
| 18 | 7x26 | BC - Bare Copper | 0.046 in | 2 | |
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene (Foam) | 0.18 in |
| PP - Polypropylene | 0.058 in |
Color Chart
| Number | Color |
|---|
| 1 | Black and Red |
Inner Shield
| Type | Material | Coverage [%] |
|---|
| Braid | Bare Copper (BC) | 95% |
Outer Shield
| Type | Layer | Material | Coverage [%] |
|---|
| Braid | 1 | Bare Copper (BC) | 95% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.275x0.514 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR | Outer Conductor DCR |
|---|
| 6.4 Ohm/1000ft | 6.4 Ohm/1000ft | 3.1 Ohm/1000ft | 3.1 Ohm/1000ft |
| 6.4 Ohm/1000ft | | | |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
|---|
| 24 pF/ft | 16.3 pF/ft |
| Operating Voltage | 300 V RMS |
|---|
Inductance
| Nominal Inductance |
|---|
| 0.097 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.2 dB/100ft |
| 5 MHz | 0.45 dB/100ft |
| 10 MHz | 0.64 dB/100ft |
| 50 MHz | 1.46 dB/100ft |
| 100 MHz | 2.1 dB/100ft |
| 200 MHz | 3.0 dB/100ft |
| 400 MHz | 4.3 dB/100ft |
| 700 MHz | 5.8 dB/100ft |
| 900 MHz | 6.7 dB/100ft |
| 1000 MHz | 7.1 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.24 ns/ft | 82% |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| Operating Temperature Range | -30°C To +75°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 67 lbs/1000ft |
|---|
| Max. Pull Tension | 114 lbs |
|---|
| Min. Bend Radius/Minor Axis | 2.75 in |
|---|
Standards
| NEC Articles | Article 800 |
|---|
| NEC/(UL) Compliance | CMG-LS |
|---|
| CEC/C(UL) Compliance | CMG-ST1 |
|---|
| CPR Euroclass | Fca |
|---|
| IEEE Compliance | Std. 45 Clause 23 |
|---|
| RG Type | 6 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Outdoor - Aerial |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | Yes |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Aerial | Yes - Black only, when supported by messenger wire |
|---|
| Suitability - Burial | No |
|---|
| Suitability - Hazardous Locations | No |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes - Black only |
|---|
| Suitability - Sunlight Resistance | No |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 FT4 Loading, Limited Smoke |
|---|
| IEC Flammability | IEC 60332-1-2, IEC 60332-3-22 |
|---|
| IEEE Flammability | IEEE 1202 |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
Product Notes
| Notes | Coax jacket diameter: .275 in, Pair jacket diameter: .204 in |
|---|
History
| Update and Revision | Revision Number: 0.306 Revision Date: 07-19-2023 |
|---|
Documentation
Product Bulletins
Catalogs