24 AWG solid bare copper conductors, polyolefin insulation, rip cord, see color code chart (below), LSZH jacket. Descending footage marked every two feet.
Specifications
Specifications
Product Overview
Suitable Applications | Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422 |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
24 | Solid | BC - Bare Copper | 4 |
Conductor Count | 8 |
---|
Total Number of Pairs | 4 |
---|
Insulation
Color Chart
Number | Color |
---|
1 | White/Blue Stripe & Blue |
2 | White/Orange Stripe & Orange |
3 | White/Green Stripe & Green |
4 | White/Brown Stripe & Brown |
Inner Jacket
Material | Nominal Diameter | Ripcord |
---|
PE - Polyethylene | 0.255 in | Yes |
Outer Shield
Outer Jacket
Material | Nominal Diameter | Ripcord |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.308 in | No |
Electrical Characteristics
Conductor DCR
Max. Conductor DCR | Max. DCR Unbalance |
---|
93.8 Ohm/km | 3 % |
Capacitance
Max. Capacitance Unbalance | Nom.Mutual Capacitance |
---|
330 | 15 pF/ft |
Delay
Frequency [MHz] | Max. Delay | Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
---|
100 MHz | 538 ns/100m | 45 ns/100m | 70% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. SRL (Structural Return Loss) | Max./Min. Input Impedance (unFitted) | Max./Min. Fitted Impedance |
---|
1 MHz | 2 dB/100m | 65.3 dB | 62.3 dB | 63 dB | 60.3 dB | 63.8 dB | 60.8 dB | 20 dB | 23 dB | 100 ± 15 | 100 ± 15 |
4 MHz | 4.1 dB/100m | 56.3 dB | 53.3 dB | 51 dB | 49.2 dB | 51.7 dB | 48.7 dB | 23 dB | 23 dB | 100 ± 15 | 100 ± 15 |
8 MHz | 5.8 dB/100m | 51.8 dB | 48.8 dB | 46 dB | 43 dB | 45.7 dB | 42.7 dB | 24.5 dB | 24.5 dB | 100 ± 15 | 100 ± 15 |
10 MHz | 6.5 dB/100m | 50.3 dB | 47.3 dB | 43 dB | 40.8 dB | 43.8 dB | 40.8 dB | 25 dB | 25 dB | 100 ± 15 | 100 ± 15 |
16 MHz | 8.2 dB/100m | 47.3 dB | 44.3 dB | 39 dB | 36 dB | 39.7 dB | 36.7 dB | 25 dB | 25 dB | 100 ± 15 | 100 ± 15 |
20 MHz | 9.3 dB/100m | 45.8 dB | 42.8 dB | 36.5 dB | 33.5 dB | 37.7 dB | 34.7 dB | 25 dB | 25 dB | 100 ± 15 | 100 ± 15 |
25 MHz | 10.4 dB/100m | 44.3 dB | 41.3 dB | 33.9 dB | 30.9 dB | 35.8 dB | 32.8 dB | 24.3 dB | 24.3 dB | 100 ± 15 | 100 ± 15 |
31.25 MHz | 11.7 dB/100m | 42.9 dB | 39.9 dB | 31 dB | 28.2 dB | 33.9 dB | 30.9 dB | 23.6 dB | 23.6 dB | 100 ± 15 | 100 ± 15 |
62.5 MHz | 17 dB/100m | 38.4 dB | 35.4 dB | 22 dB | 19 dB | 27.8 dB | 24.9 dB | 21.5 dB | 21.5 dB | 100 ± 15 | 100 ± 15 |
100 MHz | 22 dB/100m | 35.3 dB | 32.3 dB | 14 dB | 10.3 dB | 23.8 dB | 20.8 dB | 20.1 dB | 20.1 dB | 100 ± 15 | 100 ± 15 |
155 MHz | 28.1 dB/100m | 32.5 dB | 29.5 dB | 4.4 dB | 1.4 dB | 19.9 dB | 16.9 dB | 15.8 dB | | 100 ± 25 | 100 ± 15 |
200 MHz | 32 dB/100m | 30.8 dB | 27.8 dB | 4 dB | 1 dB | 17.7 dB | 14.7 dB | 15 dB | | 100 ± 25 | 100 ± 15 |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
Storage Temperature Range | -30°C To +105°C |
---|
Operating Temperature Range | -30°C To +105°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 44 lbs/1000ft |
---|
Max. Pull Tension | 35 lbs |
---|
Min. Bend Radius/Minor Axis | 3 in |
---|
Standards
NEC/(UL) Compliance | CMG-LS |
---|
CEC/C(UL) Compliance | CMG-ST1 |
---|
CPR Euroclass | Eca |
---|
IEEE Compliance | Std. 45 clause 23 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor - Euroclass Eca |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 FT4 Loading, Limited Smoke |
---|
IEC Flammability | IEC 60332-1-2, IEC 60332-3-22 |
---|
IEEE Flammability | 1202 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Product Notes
Footnote | C - CRATE REEL PUT-UP. |
---|
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. RJ-45 Compatible. Jacket marked with descending footage at 2 ft. intervals. |
---|
History
Update and Revision | Revision Number: 0.441 Revision Date: 12-19-2022 |
---|
Documentation
Brochures and Guides
All Resources
Product Certifications
Technical Information