Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® IV quad shield (Foil + 60% Braid + Foil + 40% Braid), PVC jacket.
Specifications
Specifications
Product Overview
Suitable Applications | Direct Broadcast Satellite, CATV |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
18 | Solid | BCCS - Bare Copper Covered Steel | 0.04 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene (Foam) | 0.18 in |
Outer Shield
Type | Layer | Material | Material Trade Name | Coverage [%] |
---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 2 | Aluminum | | 60% |
Tape | 3 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 4 | Aluminum | | 40% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.298 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
28 Ohm/1000ft | 4.8 Ohm/1000ft | 4.8 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
16.2 pF/ft |
Inductance
Nominal Inductance |
---|
0.097 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Return Loss
Frequency [MHz] | Min. Structural Return Loss (SRL) |
---|
5-1000 MHz | 20 dB |
1000 - 2250 MHz | 15 dB |
2250 - 3000 MHz | 10 dB |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss | Nom. Structural Return Loss (SRL) |
---|
5 MHz | 0.5 dB/100ft | 30 dB |
55 MHz | 1.4 dB/100ft | 24 dB |
211 MHz | 2.6 dB/100ft | |
500 MHz | 4.1 dB/100ft | |
750 MHz | 5.1 dB/100ft | |
862 MHz | 5.5 dB/100ft | |
1000 MHz | 6 dB/100ft | |
1450 MHz | 7.4 dB/100ft | |
1800 MHz | 8.3 dB/100ft | |
2250 MHz | 9.2 dB/100ft | |
3000 MHz | 10.5 dB/100ft | |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.2 ns/ft | 83% |
High Frequency
Max. Insertion Loss (Attenuation) |
---|
0.67 dB/100ft |
1.6 dB/100ft |
2.87 dB/100ft |
3.24 dB/100ft |
3.43 dB/100ft |
3.72 dB/100ft |
4 dB/100ft |
4.26 dB/100ft |
4.71 dB/100ft |
5.59 dB/100ft |
5.98 dB/100ft |
6.54 dB/100ft |
8 dB/100ft |
8.8 dB/100ft |
10 dB/100ft |
11 dB/100ft |
Screening
Frequency [MHz] | Shield Effectiveness |
---|
5 MHz | |
50 MHz | 110 dB |
50 MHz | |
1000 MHz | |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
Storage Temperature Range | -40°C To +80 °C |
---|
Operating Temperature Range | -40°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 33 lbs/1000ft |
---|
Max. Pull Tension | 162 lbs |
---|
Min. Bend Radius/Minor Axis | 3 in |
---|
Standards
NEC/(UL) Compliance | CATVR, CMR |
---|
CEC/C(UL) Compliance | CMG |
---|
CPR Euroclass | Eca |
---|
RG Type | 6 |
---|
Series Type | 6 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1666 Vertical Riser, UL1685 FT4 Loading |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Plenum (Y/N) | No |
---|
Plenum Number | 7916AP |
---|
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.438 Revision Date: 04-14-2023 |
---|
Documentation
Product Bulletins
Brochures
Data Sheets