Profibus, 1 Pair 22AWG (Solid) Bare Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, PVC Inner Jacket, Steel Interlock Armor, PVC Outer Jacket, PLTC CM SUN RES Profibus DP
Specifications
Specifications
Product Overview
| Suitable Applications | exposure to rodent, crush, or cut through force, harsh environment, outdoors, data transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, humidity/moisture, dust, and oil. |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Pair(s) | 1 | 22 AWG | Solid | BC - Bare Copper |
Insulation
| Element | Material | Nom. Thickness | Color Code | Notes |
|---|
| Pair(s) | PE - Polyethylene (Foam) | 0.035 in (0.89 mm) | Red & Green | Flame Retardant, Foam w/ skin |
Outer Shield
| Shield Type | Material | Coverage |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% |
| Braid | Tinned Copper (TC) | 65% |
Inner Jacket
| Material | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.315 in (8.00 mm) |
Armor
| Armor Type & Material |
|---|
| SIA - Steel Interlock Armor |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.045 in (1.1 mm) | 0.608 in (15.4 mm) |
| Overall Cable Diameter (Nominal) | 0.608 in (15.4 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|
| Pair(s) | 16 Ohm/1000ft (52 Ohm/km) | 150 Ohm | 78% | 2.3 Amps per Conductor |
| Nom. Outer Shield DCR | 3.9 Ohm/1000ft (13 Ohm/km) |
|---|
High Frequency (Nominal/Typical)
| Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
|---|
| Pair(s) | 0.2 | 0.27 dB/100ft |
| 4 | 0.67 dB/100ft |
| 16 | 1.37 dB/100ft |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) |
|---|
| 0.2 | 1.1 dB/100m (0.34 dB/100ft) |
| 4 | 2.65 dB/100m (0.808 dB/100ft) |
| 16 | 5.4 dB/100m (1.6 dB/100ft) |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CM, PLTC) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 60°C | -30°C to +75°C |
| Max. Pull Tension | 200 lbs (91 kg) |
|---|
| Bulk Cable Weight | 356 lbs/1000ft (530 kg/km) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Sunlight Resistance |
|---|
| NEC / UL Compliance | Article 725, Article 800 |
|---|
| CEC / C(UL) Compliance | CMG, HLBCD |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
History
| Update and Revision | Revision Number: 0.70 Revision Date: 05-05-2023 |
|---|
Documentation
Product Bulletins
Technical Resources
Webinars
Training
Data Sheets