RS-485, 120 Ohm, 1 pair 22AWG (7x30) tinned copper Datalene® insulaton, Overall Foil + 65% Tinned Copper Braid, PVC jacket, Steel Interlocking Armor, PVC Jacket, CM, PLTC, SUN RES
Specifications
Specifications
Product Overview
Suitable Applications | exposure to rodent, crush, or cut through force, burial, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 1 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Color Code | Notes |
---|
Pair(s) | PE - Polyethylene (Foam) | 0.029 in (0.74 mm) | White/Blue Stripe & Blue/White Stripe | HDPE |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC |
Braid | Tinned Copper (TC) | 65% | |
Inner Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.281 in (7.14 mm) |
Armor
Armor Type & Material |
---|
SIA - Steel Interlock Armor |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.045 in (1.1 mm) | 0.577 in (14.7 mm) |
Overall Cable Diameter (Nominal) | 0.577 in (14.7 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
---|
Pair(s) | 120 Ohm | 78% |
High Frequency (Nominal/Typical)
Voltage
UL Voltage Rating |
---|
300 V (CM, PLTC) |
Mechanical Characteristics
Standards and Compliance
Environmental Suitability | Sunlight Resistance |
---|
NEC / UL Compliance | Article 725, Article 800 |
---|
CEC / C(UL) Compliance | CMG HLBCD |
---|
History
Update and Revision | Revision Number: 0.59 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Solution Guides
Technical Resources
Data Sheets