Product Overview
Suitable Applications | exposure to rodent, crush, or cut through force, burial, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 3 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|
Pair(s) | PE - Polyethylene (Foam) | 0.023 in (0.58 mm) | 0.075 in (1.9 mm) | White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe, White/Green Stripe & Green/White Stripe | HDPE |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC |
Braid | Tinned Copper (TC) | 65% | |
Inner Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.053 in (1.3 mm) | 0.374 in (9.50 mm) |
Armor
Armor Type & Material |
---|
SIA - Steel Interlock Armor |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.050 in (1.3 mm) | 0.723 in (18.4 mm) |
Overall Cable Diameter (Nominal) | 0.723 in (18.4 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Shield | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
---|
Pair(s) | 17.5 Ohm/1000ft (57.4 Ohm/km) | 1.5 Ohm/1000ft (4.9 Ohm/km) | | | 120 Ohm | 78% |
| | | 11.0 pF/ft (36.1 pF/m) | 20.90 pF/ft | 120 Ohm | |
High Frequency (Nominal/Typical)
Element | Frequency [kHz] |
---|
Pair(s) | 125 |
| 500 |
High Frequency
Max. Insertion Loss (Attenuation) |
---|
0.29 dB/100ft |
0.5 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CM, PLTC) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
60°C | -25°C to +60°C |
Max. Pull Tension | 200 lbs (91 kg) |
---|
Bulk Cable Weight | 427 lbs/1000ft (635 kg/km) |
---|
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | FT4 |
---|
NEC / UL Compliance | Article 725, Article 800, CM, PLTC |
---|
CEC / C(UL) Compliance | CMG HLBCD |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.65 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation