Fieldbus, 2 Conductor 16AWG (7x24H) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, Orange PVC Outer Jacket, CM
Specifications
Specifications
Product Overview
| Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 16 | 7x24 | TC - Tinned Copper | 1 |
Insulation
| Material |
|---|
| PP - Polypropylene |
Color Chart
| Number | Color |
|---|
| 1 | Blue & Orange |
Outer Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | 1 | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 20 | 7x28 |
| Braid | 2 | Tinned Copper (TC) | | 65% | | | |
Outer Jacket
| Material | Nominal Diameter | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.34 in | Yes |
Electrical Characteristics
Conductor DCR
| Max. Outer Shield DCR | Nominal Conductor DCR |
|---|
| 4.9 Ohm/1000ft | 4.2 Ohm/1000ft |
Capacitance
| Max. Capacitance Unbalance | Nom. Capacitance Conductor to Shield | Nom.Mutual Capacitance |
|---|
| 1.2 pF/ft | 45 pF/ft | 24 pF/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 100 Ohm |
High Frequency (Nominal/Typical)
| Nom. Insertion Loss |
|---|
| 0.066 dB/100ft |
Delay
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 66% |
High Frequency
| Max. Insertion Loss (Attenuation) | Max./Min. Input Impedance (unFitted) |
|---|
| 0.091 dB/100ft | 100 Ohm |
Current
| Element | Max. Recommended Current [A] |
|---|
| Per Conductor | 8 Amps per Conductor |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
| Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
|---|
| Other Electrical Characteristic 2 | 31.25 KBits/sec |
|---|
Temperature Range
| UL Temp Rating | 90°C |
|---|
| Operating Temperature Range | -30°C to +90°C |
|---|
Mechanical Characteristics
| Oil Resistance | Yes |
|---|
| UV Resistance | Yes |
|---|
| Bulk Cable Weight | 79 lbs |
|---|
| Max. Pull Tension | 84 lbs |
|---|
| Min. Bend Radius/Minor Axis | 3.4 in |
|---|
Standards
| NEC Articles | Article 725, Article 727, Article 800 |
|---|
| NEC/(UL) Compliance | CM, ITC, PLTC |
|---|
| CEC/C(UL) Compliance | CM |
|---|
| CPR Euroclass | Eca |
|---|
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Burial | Yes - UL |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 UL Loading |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
History
| Update and Revision | Revision Number: 0.506 Revision Date: 05-05-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Data Sheets