Belden

1336A - Fieldbus, 2 C #14 Str TC, PO Ins, OS+TC Brd, PVC Jkt, PLTC

(No reviews yet) Write a Review
SKU:
1336A
Shipping:
Calculated at Checkout
$0.00

Description

Fieldbus, 2 Conductor 14AWG (7x22H) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, Orange PVC Outer Jacket, PLTC

Specifications

Specifications

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Pairs
147x22TC - Tinned Copper1
Conductor Count2

Insulation

Material
PP - Polypropylene

Color Chart

NumberColor
1Blue & Orange

Outer Shield

TypeLayerMaterialMaterial Trade NameCoverage [%]Drainwire MaterialDrainwire AWGDrainwire Construction n x D
Tape1Bi-Laminate (Alum+Poly)Beldfoil®100%TC - Tinned Copper187x26
Braid2Tinned Copper (TC)65%

Outer Jacket

MaterialNominal DiameterRipcord
PVC - Polyvinyl Chloride0.43 inYes

Electrical Characteristics

Conductor DCR

Max. Outer Shield DCRNominal Conductor DCR
4.9 Ohm/1000ft2.5 Ohm/1000ft

Capacitance

Max. Capacitance UnbalanceNom. Capacitance Conductor to ShieldNom.Mutual Capacitance
1.2 pF/ft45 pF/ft24 pF/ft

Impedance

Nominal Characteristic Impedance
100 Ohm

High Frequency (Nominal/Typical)

Nom. Insertion Loss
0.062 dB/100ft

Delay

Nominal Velocity of Propagation (VP) [%]
66%

High Frequency

Max. Insertion Loss (Attenuation)Max./Min. Input Impedance (unFitted)
0.091 dB/100ft100 Ohm

Current

ElementMax. Recommended Current [A]
Per Conductor5.2 Amps per Conductor

Voltage

UL Voltage Rating
300 V RMS
Electrical Characteristics NotesMax Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft
Other Electrical Characteristic 231.25 KBits/sec

Temperature Range

UL Temp Rating90°C
Operating Temperature Range-30°C to +90°C

Mechanical Characteristics

Oil ResistanceYes
UV ResistanceYes
Max. Pull Tension131 lbs
Min. Bend Radius/Minor Axis4.3 in

Standards

CPR EuroclassEca

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes
MII Order #39 (China RoHS)Yes

Suitability

Suitability - BurialYes - UL
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
IEC FlammabilityIEC 60332-1-2
UL voltage rating300 V RMS

Plenum/Non-Plenum

Plenum (Y/N)No

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

History

Update and RevisionRevision Number: 0.503 Revision Date: 05-05-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Put-Up Type|Length|UPC
Variant_Options 1336A 0061640:
1336A 0061640|Blue, Light|Reel|1,640 ft|612825112235
Variant_Options 1336A 0063280:
1336A 0063280|Blue, Light|Reel|3,280 ft|612825112242
Variant_Options 1336A 0031000:
1336A 0031000|Orange|Reel|1,000 ft|612825112211
Variant_Options 1336A 0031640:
1336A 0031640|Orange|Reel|1,640 ft|612825112228
View AllClose