Blue Hose® for Data Highway Plus, 1 Pair 20AWG (7x28) Tinned Copper, PE Insulation Blue & Clear, Overall Beldfoil®+Tinned Copper Braid(55%) Shield, PVC Inner Jacket, Steel Interlock Armor, Blue PVC Outer Jacket, CM
Specifications
Specifications
Product Overview
| Suitable Applications | exposure to rodent, crush, or cut through force, harsh environment, Allen Bradley Data Highway communication interface between PLC processors, I/O devices, operator interfaces, computers and other intelligent devices, PLC processor interlocking, peer-to-peer messaging, remote programming, troubleshooting, I/O updates, etc. |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Pair(s) | 1 | 20 AWG | 7x28 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Color Code | Notes |
|---|
| Pair(s) | PE - Polyethylene | 0.019 in (0.48 mm) | Clear & Blue | Twinax with rod fillers |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC |
| Braid | Tinned Copper (TC) | 55% | |
Inner Jacket
| Material | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.238 in (6.05 mm) |
Armor
| Armor Type & Material |
|---|
| SIA - Steel Interlock Armor |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.050 in (1.3 mm) | 0.541 in (13.7 mm) |
| | 0.563 in (14.3 mm) |
| Overall Cable Diameter (Nominal) | 0.541 in (13.7 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
|---|
| Pair(s) | 9.5 Ohm/1000ft (31 Ohm/km) | 19.7 pF/ft (64.6 pF/m) | 36 pF/ft | 78 Ohm | 66% |
| Nom. Outer Shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
|---|
High Frequency (Nominal/Typical)
| Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
|---|
| Pair(s) | 1 | 0.6 dB/100ft |
| 10 | 2.1 dB/100ft |
| 50 | 5 dB/100ft |
| 100 | 7.5 dB/100ft |
| 200 | 11 dB/100ft |
| 400 | 16 dB/100ft |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CM) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 60°C | -40°C to +60°C |
| Max. Pull Tension | 205 lbs (93.0 kg) |
|---|
| Bulk Cable Weight | 224 lbs/1000ft (333 kg/km) |
|---|
Standards and Compliance
| Flammability / Reaction to Fire | UL1685 UL Loading, FT4 |
|---|
| NEC / UL Compliance | Article 725, Article 800, CM, CL2 |
|---|
| CEC / C(UL) Compliance | CM, CMG, HLBCD |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| Other Standard Compliance(s) | Allen Bradley Part No. 1770-CD |
|---|
History
| Update and Revision | Revision Number: 0.251 Revision Date: 05-05-2023 |
|---|
Documentation
Product Bulletins
Data Sheets