20 AWG solid .032” bare copper conductors, gas-injected foam HDPE insulation, Duofoil® (100% Coverage) plus a tinned copper braid shield (95% coverage), individual PVC jackets.
Specifications
Specifications
Product Overview
| Suitable Applications | RGB, VGA, SVGA, XGA, SXGA, UXGA, HDTV, LCD, Plasma, Digital Signage, Component Video, Video Mult, Animation, Special Effects, Suitable for use in Risers |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 20 | Solid | BC - Bare Copper | 0.032 in | 6 |
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene (Foam) | 0.145 in |
Color Chart
| Number | Color |
|---|
| 1 | Red |
| 2 | Green |
| 3 | Blue |
| 4 | White |
| 5 | Yellow |
Inner Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] |
|---|
| Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 2 | Tinned Copper (TC) | | 95% |
Inner Jacket
| Material | Nominal Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.235 in |
Outer Jacket
| Material | Nominal Diameter |
|---|
| Banana Peel (No Overall Jacket) | 0.699 in |
Construction and Dimensions
Cabling
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR | Outer Conductor DCR |
|---|
| 10 Ohm/1000ft | 10 Ohm/1000ft | 3.8 Ohm/1000ft | 3.8 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 16.2 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.107 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
Return Loss
| Frequency [MHz] | Minimum Return (RL) |
|---|
| 5-475 MHz | 20 dB |
| 475-525 MHz | 15 dB |
| 525-850 MHz | 20 dB |
| 850-4500 MHz | 15 dB |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.3 dB/100ft |
| 3.6 MHz | 0.6 dB/100ft |
| 10 MHz | 0.9 dB/100ft |
| 71.5 MHz | 2.1 dB/100ft |
| 135 MHz | 2.7 dB/100ft |
| 270 MHz | 3.8 dB/100ft |
| 360 MHz | 4.4 dB/100ft |
| 540 MHz | 5.5 dB/100ft |
| 720 MHz | 6.4 dB/100ft |
| 750 MHz | 6.5 dB/100ft |
| 1000 MHz | 7.6 dB/100ft |
| 1500 MHz | 9.4 dB/100ft |
| 2500 MHz | 12.4 dB/100ft |
| 3000 MHz | 13.8 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.22 ns/ft | 83% |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| Non-UL Temp Rating | 75°C |
|---|
| UL Temp Rating | 60°C |
|---|
| Operating Temperature Range | -35°C To +75°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 208 lbs/1000ft |
|---|
| Max. Pull Tension | 432 lbs |
|---|
| Min. Bend Radius/Minor Axis | 10 in |
|---|
Standards
| NEC/(UL) Compliance | CMR |
|---|
| CEC/C(UL) Compliance | CMG |
|---|
| RG Type | 59 |
|---|
| Series Type | 59 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor/Outdoor |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1666 Vertical Shaft |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
Product Notes
History
| Update and Revision | Revision Number: 0.349 Revision Date: 11-09-2022 |
|---|
Documentation
Catalogs
Technical Resources
Data Sheets