ANALOG AUDIO 4 PAIR 24AWG/0.22mm², BELDFOIL, LSZH-C
Specifications
Specifications
Product Overview
Suitable Applications | 4-pair 24AWG halogen-free multi-core cable; For analogue audio |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Construction n x D |
---|
24 | 7x32 | TC - Tinned Copper | 7x0.20 mm |
Conductor Count | 8 |
---|
Total Number of Pairs | 4 |
---|
Insulation
Type | Material | Nominal Diameter | Diameter +/- Tolerance |
---|
Insulation | PE - Polyethylene | 1.02 mm | 0.05 mm |
Color Chart
Number | Color |
---|
Pair 1 t/m 4 | Red & Black |
Inner Shield
Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D | Drainwire Position |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | Stranded tinned copper | 24 | 7x0.20 mm | Under shielding foil |
Table Notes | Aluminum inside |
---|
Inner Jacket
Material | Nominal Diameter |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 2.86 mm |
Table Notes | Jacket single element, elements are numbered 1 - 4 |
---|
Outer Shield
Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | TC - Tinned Copper | 7xAWG26 | 7x0.40 mm |
Outer Jacket
Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 8.90 mm | 0.40 mm | 1.00 mm |
Construction and Dimensions
Cabling
Description |
---|
1 center filler + 4 pairs |
Min Elongation at Breakof Jacket | 125 % |
---|
Min Tensile Strength of Jacket | 9 MPa |
---|
Electrical Characteristics
Conductor DCR
Max. Conductor DCR | Nominal Inner Shield DCR |
---|
88.5 Ohm/km | 52 Ohm/km |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
---|
92 pF/m | 180 pF/m |
Inductance
Nominal Inductance |
---|
0.75 µH/m |
Temperature Range
Other Temp Range | -30 to +70 °C |
---|
Mechanical Characteristics
Max. Pull Tension | 246 N |
---|
Min. Bend Radius During Installation | 89 mm |
---|
Min. Bend Radius During Operation | 133.5 mm |
---|
Standards
CPR Euroclass | Dca-s1,d1,a1 |
---|
CENELEC Compliance | EN 50290-2-20 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor - Euroclass Dca |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2, IEC 60332-3-24 |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
---|
History
Update and Revision | Revision Number: 0.188 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets