Audio Snake Cable, CM-Rated, 16-24 AWG tinned copper pairs, polyolefin insulation, individually shielded with Beldfoil® bonded to numbered/color-coded PVC jackets so both strip simulteaneously, overall Beldfoil® shield, drain, flexible PVC jacket
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
|---|
| 24 | 7x32 | TC - Tinned Copper | 0.024 in | 16 |
| Conductor Count | 32 |
|---|
| Total Number of Pairs | 16 |
|---|
Insulation
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PP - Polypropylene | 0.04 in | 0.008 in |
Color Chart
| Number | Color |
|---|
| 1 | Brown |
| 2 | Red |
| 3 | Orange |
| 4 | Yellow |
| 5 | Green |
| 6 | Blue |
| 7 | Purple |
| 8 | Gray |
| 9 | White |
| 10 | Black |
| 11 | Tan |
| 12 | Pink |
| 13 | Gray/Brown |
| 14 | Gray/Red |
| 15 | Gray/Orange |
| 16 | Gray/Yellow |
Color Chart 2
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.024 in | 24 | 7x32 |
Inner Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PVC - Polyvinyl Chloride | 0.113 in | 0.015 in |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.046 in | 18 | 7x26 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.628 in | 0.056 in | Yes |
Electrical Characteristics
Conductor DCR
| Individual Pair Nominal Shield DCR | Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance |
|---|
| 15.9 Ohm/1000ft | 23.3 Ohm/1000ft | 23.3 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 31 pF/ft | 58 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.18 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 50 Ohm |
Delay
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 66% |
Current
| Max. Recommended Current [A] |
|---|
| 1.05 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| Operating Temperature Range | -35°C To +75°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 225 lbs/1000ft |
|---|
| Max. Pull Tension | 286.4 lbs |
|---|
| Min. Bend Radius/Minor Axis | 6.5 in |
|---|
Standards
| NEC/(UL) Compliance | CM |
|---|
| CEC/C(UL) Compliance | CM |
|---|
| CPR Euroclass | Eca |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
Flammability, LS0H, Toxicity Testing
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
History
| Update and Revision | Revision Number: 0.426 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets