Broadband Coax, Series 11, 14 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, Foil + 60% Aluminum Braid Shield, PVC Jacket, CM
Specifications
Specifications
Product Overview
Suitable Applications | Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas |
---|
Construction Details
Conductor
Element | Size | Stranding | Nom. Diameter | Material |
---|
Coax(es) | 14 AWG | Solid | 0.064 in | BCCS - Bare Copper Covered Steel |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
PE - Polyethylene (Foam) | 0.280 in (7.11 mm) | White |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
2 | Braid | Aluminum | | 60% |
Outer Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.393 in (9.98 mm) |
Overall Cable Diameter (Nominal) | 0.393 in (9.98 mm) |
---|
Electrical Characteristics
Return Loss
Frequency | Min. Structural Return Loss |
---|
5 - 1000 MHz | 20 dB |
Attenuation
Frequency | Max. Attenuation |
---|
5 MHz | 0.38 dB/100ft |
55 MHz | 0.96 dB/100ft |
211 MHz | 1.90 dB/100ft |
250 MHz | 2.05 dB/100ft |
270 MHz | 2.13 dB/100ft |
300 MHz | 2.25 dB/100ft |
330 MHz | 2.35 dB/100ft |
350 MHz | 2.42 dB/100ft |
400 MHz | 2.60 dB/100ft |
450 MHz | 2.75 dB/100ft |
500 MHz | 2.90 dB/100ft |
550 MHz | 3.04 dB/100ft |
600 MHz | 3.18 dB/100ft |
750 MHz | 3.65 dB/100ft |
870 MHz | 4.06 dB/100ft |
1000 MHz | 4.35 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
11 Ohm/1000ft (36 Ohm/km) | 4.1 Ohm/1000ft (13 Ohm/km) | 16.3 pF/ft (53.5 pF/m) | 75 Ohm | 83% |
Voltage
UL Voltage Rating |
---|
300 V (CM), (CM) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
75°C | -40°C to +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
3.9 in (99 mm) | 3.9 in (99 mm) |
Max. Pull Tension | 199 lbs (90.3 kg) |
---|
Bulk Cable Weight | 199 |
---|
Standards and Compliance
Environmental Suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger wire |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | UL1685 UL Loading, FT4 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | Article 800, CM, CATV |
---|
CEC / C(UL) Compliance | CM |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Other Standard Compliance(s) | ANSI/SCTE 74 |
---|
Plenum Number | 1523AP |
---|
History
Update and Revision | Revision Number: 0.494 Revision Date: 04-14-2023 |
---|
Documentation
Product Bulletins
Brochures
Compliance Documentation
Data Sheets