Broadband Coax, Series 11, 14 AWG Solid Bare Copper Covered Steel Conductor, FEP Insulation, Foil + 60% Aluminum Braid Shield, PVDF Jacket, CMP
Specifications
Specifications
Product Overview
| Suitable Applications | Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas |
|---|
Construction Details
Conductor
| Size | Stranding | Nom. Diameter | Material |
|---|
| 14 AWG | Solid | 0.064 in | BCCS - Bare Copper Covered Steel |
Insulation
| Material | Nom. Insulation Diameter | Color Code |
|---|
| FEP - Fluorinated Ethylene Propylene (Foam) | 0.274 in (6.96 mm) | White |
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
| 2 | Braid | Aluminum | | 60% |
Outer Jacket
| Material | Nom. Diameter |
|---|
| PVDF - Polyvinylidene Fluoride | 0.348 in (8.84 mm) |
| Overall Cable Diameter (Nominal) | 0.348 in (8.84 mm) |
|---|
Electrical Characteristics
Return Loss
| Frequency | Min. Structural Return Loss |
|---|
| 5 - 1000 MHz | 20 dB |
Attenuation
| Frequency | Max. Attenuation |
|---|
| 5 MHz | 0.38 dB/100ft |
| 55 MHz | 1.12 dB/100ft |
| 211 MHz | 2.24 dB/100ft |
| 240 MHz | 2.43 dB/100ft |
| 270 MHz | 2.59 dB/100ft |
| 300 MHz | 2.75 dB/100ft |
| 325 MHz | 2.92 dB/100ft |
| 350 MHz | 3.08 dB/100ft |
| 400 MHz | 3.34 dB/100ft |
| 450 MHz | 3.64 dB/100ft |
| 500 MHz | 3.92 dB/100ft |
| 550 MHz | 4.19 dB/100ft |
| 600 MHz | 4.48 dB/100ft |
| 750 MHz | 5.31 dB/100ft |
| 870 MHz | 5.86 dB/100ft |
| 1000 MHz | 6.53 dB/100ft |
Electricals
| Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|
| 12 Ohm/1000ft | 4.1 Ohm/1000ft (13 Ohm/km) | 16.3 pF/ft (53.5 pF/m) | 75 Ohm | 83% |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 150°C | -20°C to +150°C |
Bend Radius
| Installation Min. |
|---|
| 3.5 in (89 mm) |
| Max. Pull Tension | 260 lbs (120 kg) |
|---|
| Bulk Cable Weight | 57 lbs/1000ft (85 kg/km) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor, Aerial - Black only, When supported by messenger wire |
|---|
| Sustainability | CA Prop 65 |
|---|
| Flammability / Reaction to Fire | NFPA 262 |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| CEC / C(UL) Compliance | CMP |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
| Non-Plenum Number | 1523A |
|---|
History
| Update and Revision | Revision Number: 0.496 Revision Date: 04-13-2023 |
|---|
Documentation
Product Bulletins
Brochures
Compliance Documentation
Data Sheets