Category 5e Premise Horizontal Cable (200MHz), Indoor/Outdoor, 4 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Riser-CMR/CMX Outdoor, UV Resistant PVC Jacket
Specifications
Specifications
Product Overview
Suitable Applications | Indoor/Outdoor, Premise Horizontal Cable, Ethernet 1000BASE-T, PoE++, PoE+, PoE |
---|
Construction Details
Conductor
Size | Stranding | Material | Number of Pairs |
---|
24 AWG | Solid | BC - Bare Copper | 4 |
Insulation
Material | Color Code |
---|
PO - Polyolefin | White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown |
Outer Jacket
Material | Nom. Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.220 in (5.59 mm) | Yes |
Overall Cable Diameter (Nominal) | 0.220 in (5.59 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|
93.8 Ohm/km (28.6 Ohm/1000ft) | 330 pF/100m |
Delay
Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
---|
100 MHz | 537.6 ns/100m | 45 ns/100m | 68% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] |
---|
1 | 2.0 dB/100m | 65.3 | 62.3 | 63.3 | 60.3 | 63.8 | 60.8 | 20.0 | 100 ± 15 | 100 ± 15 |
4 | 4.1 dB/100m | 56.3 | 53.3 | 52.2 | 49.2 | 51.7 | 48.7 | 23.0 | 100 ± 15 | 100 ± 15 |
8 | 5.8 dB/100m | 51.8 | 48.8 | 46.0 | 43.0 | 45.7 | 42.7 | 24.5 | 100 ± 15 | 100 ± 15 |
10 | 6.5 dB/100m | 50.3 | 47.3 | 43.8 | 40.8 | 43.8 | 40.8 | 25.0 | 100 ± 15 | 100 ± 15 |
16 | 8.2 dB/100m | 47.3 | 44.2 | 39.0 | 36.0 | 39.7 | 36.7 | 25.0 | 100 ± 15 | 100 ± 15 |
20 | 9.3 dB/100m | 45.8 | 42.8 | 36.5 | 33.5 | 37.7 | 34.7 | 25.0 | 100 ± 15 | 100 ± 15 |
25 | 10.4 dB/100m | 44.3 | 41.3 | 33.9 | 30.9 | 35.8 | 32.8 | 24.3 | 100 ± 15 | 100 ± 15 |
31.25 | 11.7 dB/100m | 42.9 | 39.9 | 31.2 | 28.2 | 33.9 | 30.9 | 23.6 | 100 ± 15 | 100 ± 15 |
62.5 | 17.0 dB/100m | 38.4 | 35.4 | 21.4 | 18.4 | 27.8 | 24.8 | 21.5 | 100 ± 15 | 100 ± 15 |
100 | 22.0 dB/100m | 35.3 | 32.3 | 13.3 | 10.3 | 23.8 | 20.8 | 20.1 | 100 ± 15 | 100 ± 15 |
155 | 28.1 dB/100m | 32.5 | 29.4 | 4.4 | 1.4 | 19.9 | 16.9 | 15.8 | 100 ± 25 | 100 ± 15 |
200 | 32.4 dB/100m | 30.8 | 27.8 | | | 17.7 | 14.7 | 15.0 | 100 ± 25 | 100 ± 15 |
Voltage
UL Voltage Rating |
---|
300 V (CMR), 300 V (CMX-Outdoor) |
Mechanical Characteristics
Temperature
UL Temperature | Operating | Installation | Storage |
---|
90°C | -40°C To +75°C | -25°C To +75°C | -40°C To +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
1.0 in (25 mm) | 2.25 in (57.2 mm) |
Max. Pull Tension | 25 lbs (11 kg) |
---|
Bulk Cable Weight | 23 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Aerial - When supported by messenger wire |
---|
Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
---|
Flammability / Reaction to Fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
---|
CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
---|
NEC / UL Compliance | Article 800 |
---|
CEC / C(UL) Compliance | CMX-Outdoor |
---|
ICEA Compliance | S-90-661, S-56-434, S-99-689, S-100-685 |
---|
IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3 |
---|
NEMA Compliance | NEMA WC-63.1 |
---|
Data Category | Category 5e |
---|
TIA/EIA Compliance | ANSI/TIA-568.2-D Category 5e |
---|
Third Party Performance Verification | Category 5e |
---|
ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Plenum Number | 1585A |
---|
Non-Plenum Number | 1583A |
---|
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. |
---|
History
Update and Revision | Revision Number: 0.510 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Warranties
Reference Manuals
Compliance Documentation
Data Sheets