Series 11, 14 AWG solid .064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® IV quad shield (Foil + 60% Braid + Foil + 40% Braid), polyethylene jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
14 | Solid | BCCS - Bare Copper Covered Steel | 0.064 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene (Foam) | 0.28 in |
Outer Shield
Type | Layer | Material | Material Trade Name | Coverage [%] |
---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 2 | Aluminum | | 60% |
Tape | 3 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 4 | Aluminum | | 40% |
Outer Jacket
Material | Nominal Diameter |
---|
PE - Polyethylene | 0.407 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
11 Ohm/1000ft | 3 Ohm/1000ft | 3 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
16.2 pF/ft |
Inductance
Nominal Inductance |
---|
0.097 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Return Loss
Frequency [MHz] | Min. Structural Return Loss (SRL) |
---|
5 - 1000 MHz | 20 dB |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.2 ns/ft | 83% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) |
---|
5 MHz | 0.38 dB/100ft |
55 MHz | 0.96 dB/100ft |
211 MHz | 1.9 dB/100ft |
270 MHz | 2.13 dB/100ft |
300 MHz | 2.25 dB/100ft |
350 MHz | 2.42 dB/100ft |
400 MHz | 2.6 dB/100ft |
450 MHz | 2.75 dB/100ft |
550 MHz | 3.04 dB/100ft |
750 MHz | 3.65 dB/100ft |
870 MHz | 4.06 dB/100ft |
1000 MHz | 4.35 dB/100ft |
Voltage
Non-UL Voltage Rating |
---|
300 V RMS |
Temperature Range
Operating Temperature Range | -55°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 52 lbs/1000ft |
---|
Max. Pull Tension | 308 lbs |
---|
Min. Bend Radius/Minor Axis | 4.25 in |
---|
Standards
Applicable Environmental and Other Programs
Environmental Space | Outdoor - Water Exposure |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Burial | Yes |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.386 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Brochures
Data Sheets