DNV GL, Shipboard, Category 5e Premise Horizontal Cable (100MHz), 4-Pair, 24 AWG solid bare copper conductors, F/UTP, Polyethylene insulation, Beldfoil® shield, AWG 26 solid tinned copper drainwire, LSZH jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Horizontal and building backbone cable; Support current and future Category 5e applications, such as: 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM |
|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
|---|
Construction Details
Conductor
| Element | Size | Stranding | Material | Number of Pairs | Number of Element |
|---|
| Individual Pair | 24 AWG | Solid | BC - Bare Copper | 4 | 8 |
Insulation
| Element | Material | Nom. Insulation Diameter | Color Code |
|---|
| Individual Pair | PE - Polyethylene | 1.05 mm (0.0413 in) | White/Blue & Blue, White/Green & Green, White/Orange & Orange, White/Brown & Brown |
Cable Core
| Description |
|---|
| 4 pairs twisted together covered with a polyester foil |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 26 AWG (Solid) TC |
| Table Notes | Aluminum facing outside in contact with drain wire |
|---|
Outer Jacket
| Material | Nom. Diameter |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 6.6 mm (0.26 in) |
| Overall Cable Diameter (Nominal) | 6.6 mm (0.26 in) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
|---|
| 95 Ohm/km | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
Delay
| Max. Delay Skew | Nom. Velocity of Prop. |
|---|
| 40 ns/100m | 69% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|
| 1 | 2.1 dB/100m | 65.3 | 62.3 | 63.2 | 60.2 | 64 | 61 | 20 | 40 | 35 |
| 4 | 4 dB/100m | 56.3 | 53.3 | 52.32 | 49.3 | 52 | 49 | 23 | 34 | 23 |
| 10 | 6.3 dB/100m | 50.3 | 47.3 | 44 | 41 | 44 | 41 | 25 | 30 | 15 |
| 16 | 8 dB/100m | 47.2 | 44.2 | 39.2 | 36.2 | 39.9 | 36.9 | 25 | 28 | 10.9 |
| 20 | 9 dB/100m | 45.8 | 42.8 | 36.8 | 33.8 | 38 | 35 | 25 | 27 | 9 |
| 31.25 | 11.4 dB/100m | 42.9 | 39.9 | 31.5 | 28.5 | 34.1 | 31.5 | 23.6 | 25.1 | 5.5 |
| 62.5 | 16.5 dB/100m | 38.4 | 35.4 | 21.9 | 18.9 | 28.1 | 25.1 | 21.5 | 22 | |
| 100 | 21.3 dB/100m | 35.3 | 32.3 | 14 | 11 | 24 | 21 | 20.1 | 20 | |
| Table Notes | Limits below 4 MHz are for information only.
Reference standard: IEC 61156-5 |
|---|
Transfer Impedance
| Frequency | Max. Transfer Impedance |
|---|
| 1 Mhz | Max. 50 mOhm/m |
| 10 Mhz | Max. 100 mOhm/m |
| 30 Mhz | Max. 200 mOhm/m |
| 100 Mhz | Max. 1000 mOhm/m |
| Transfer Impedance Class | Grade 2 |
|---|
| Screening Class | Type II |
|---|
| Table Notes | Coupling Attenuation |
|---|
Voltage
Mechanical Characteristics
Temperature
| Operating | Installation |
|---|
| -30°C to +60°C | 0°C To +50°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 24 mm (0.94 in) | 48 mm |
| Max. Pull Tension | 72 N (16 lbf) |
|---|
| Bulk Cable Weight | 39 kg/km |
|---|
Standards and Compliance
| Environmental Suitability | Indoor |
|---|
| Flammability / Reaction to Fire | IEC 60332-1-2 |
|---|
| IEEE Compliance | PoE: IEEE 802.3bt Type 1, Type 2, Type 3 |
|---|
| Data Category | Category 5e |
|---|
| TIA/EIA Compliance | ANSI/TIA 568.2-D |
|---|
| Third Party Performance Verification | DNV GL certification |
|---|
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61034-2 - Smoke Density Min Transmittance = 60% |
|---|
| CENELEC Compliance | EN 50173-1, Segregation class according EN50174-2 = c |
|---|
| European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
|---|
| European Directive Compliance | EU CE Mark |
|---|