RG-402/U type, 19 AWG solid .036" silver-plated copper-covered steel conductor, TFE Teflon® Insulation, copper-tin composite shield (100% coverage), PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
19 | Solid | SCCS - Silvered Copper Covered Steel | 0.036 in | 1 |
Insulation
Material | Material Trade Name | Nominal Diameter |
---|
PTFE - Polytetrafluoroethylene | Teflon® | 0.116 in |
Outer Shield
Type | Layer | Material | Coverage [%] |
---|
Tape | 1 | Bare Copper (BC) | 100% |
Braid | 2 | Tinned Copper (TC + Tin Filled) | 100% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.178 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
20.5 Ohm/1000ft | 20.5 Ohm/1000ft | 4.5 Ohm/1000ft | 4.5 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
29.5 pF/ft |
Inductance
Nominal Inductance |
---|
0.07 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
50 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
500 MHz | 8 dB/100ft |
1000 MHz | 12 dB/100ft |
2000 MHz | 18.1 dB/100ft |
3000 MHz | 22.9 dB/100ft |
5000 MHz | 31 dB/100ft |
7000 MHz | 37.8 dB/100ft |
10000 MHz | 46.6 dB/100ft |
15000 MHz | 59.1 dB/100ft |
18000 MHz | 65.8 dB/100ft |
20000 MHz | 70 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.46 ns/ft | 70% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) |
---|
500 MHz | 9.5 dB/100ft |
1000 MHz | 14.5 dB/100ft |
3000 MHz | 26.5 dB/100ft |
5000 MHz | 36 dB/100ft |
10000 MHz | 54 dB/100ft |
20000 MHz | 84 dB/100ft |
Power Rating
Frequency [MHz] | Max. Power Rating [W] | Nominal Power Rating [W] |
---|
500 MHz | 600 W | 600 W |
1,000 MHz | 401 W | 401 W |
2,000 MHz | 268 W | 268 W |
3,000 MHz | 211 W | 211 W |
5,000 MHz | 157 W | 157 W |
7,000 MHz | 129 W | 129 W |
10,000 MHz | 105 W | 105 W |
15,000 MHz | 83 W | 83 W |
18,000 MHz | 74 W | 74 W |
20,000 MHz | 70 W | 70 W |
Voltage
Non-UL Voltage Rating | UL Voltage Rating |
---|
1900 V RMS | 30 V RMS |
VSWR
Element | Frequency [MHz] | Max. VSWR |
---|
Ramp Function, End Points | 500 MHz | 1.1 |
| 20000 MHz | 1.3 |
Temperature Range
Non-UL Temp Rating | 105°C |
---|
UL Temp Rating | 105°C |
---|
Operating Temperature Range | -40°C To +105°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 32 lbs/1000ft |
---|
Max. Pull Tension | 70 lbs |
---|
Min Bend Radius (Overall) | 1.5 in |
---|
Min. Bend Radius During Installation | 0.25 in |
---|
Min Flexing Radius | 0.75 in |
---|
Standards
UL AWM Style Compliance | AWM 10245 |
---|
RG Type | 402 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | Horizontal Wire |
---|
UL voltage rating | 30 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP., V - 250' PUT-UP EXACT LENGTH MAXIMUM OF 3 PIECES, MINIMUM LENGTH 50'. 500' PUT-UP EXACT LENGTH MAXIMUM OF 5 PIECES, MINIMUM LENGTH 50'. 1000' PUT-UP EXACT LENGTH MAXIMUM OF 8 PIECES, MINIMUM LENGTH 50'. |
---|
Product Notes
Notes | Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. |
---|
History
Update and Revision | Revision Number: 0.401 Revision Date: 11-09-2022 |
---|