Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
|---|
| 24 | 7x32 | TC - Tinned Copper | 0.024 in | 2 |
| Conductor Count | 4 |
|---|
| Total Number of Pairs | 2 |
|---|
Insulation
| Material | Material Trade Name | Nominal Diameter | Nominal Wall Thickness |
|---|
| PE - Polyethylene (Foam) | Datalene® | 0.068 in | 0.022 in |
Color Chart
| Number | Color |
|---|
| 1 | Brown and Numbered 1 |
| 2 | Red and Numbered 2 |
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.024 in | 24 | Stranded |
| Table Notes | Indiv. Foil tapes bonded to inner jacket |
|---|
Inner Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PVC - Polyvinyl Chloride | 0.167 in | 0.014 in |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.060 in | 16 | Stranded |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.409 in | 0.034 in | Yes |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance |
|---|
| 23.7 Ohm/1000ft | 23.7 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 12 pF/ft | 26 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.18 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 110 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 0.384 MHz | 0.69 dB/100ft |
| 0.7056 MHz | 0.93 dB/100ft |
| 0.768 MHz | 0.96 dB/100ft |
| 1.024 MHz | 1.07 dB/100ft |
| 1.4112 MHz | 1.19 dB/100ft |
| 1.536 MHz | 1.21 dB/100ft |
| 2.048 MHz | 1.31 dB/100ft |
| 2.8224 MHz | 1.41 dB/100ft |
| 3.072 MHz | 1.45 dB/100ft |
| 4.096 MHz | 1.57 dB/100ft |
| 5.6448 MHz | 1.76 dB/100ft |
| 6.144 MHz | 1.83 dB/100ft |
| 8.192 MHz | 2.01 dB/100ft |
| 11.2896 MHz | 2.24 dB/100ft |
| 12.288 MHz | 2.3 dB/100ft |
| 24.576 MHz | 3.08 dB/100ft |
Delay
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 76% |
High Frequency
| Frequency [MHz] |
|---|
| 0.384 MHz |
| 0.7056 MHz |
| 0.768 MHz |
| 1.024 MHz |
| 1.4112 MHz |
| 1.536 MHz |
| 2.048 MHz |
| 2.8224 MHz |
| 3.072 MHz |
| 4.096 MHz |
| 5.6448 MHz |
| 6.144 MHz |
| 8.192 MHz |
| 11.2896 MHz |
| 12.288 MHz |
| 24.576 MHz |
Current
| Max. Recommended Current [A] |
|---|
| 2.75 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| UL Temp Rating | 60°C |
|---|
| Operating Temperature Range | -30°C To +60°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 69 lbs/1000ft |
|---|
| Max. Pull Tension | 73 lbs |
|---|
| Min. Bend Radius/Minor Axis | 4.25 in |
|---|
Standards
| NEC/(UL) Compliance | CMG |
|---|
| CEC/C(UL) Compliance | CMG |
|---|
| Other Specification | AES/EBU |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | Yes |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 FT4 Loading |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Product Notes
| Notes | Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |
|---|
History
| Update and Revision | Revision Number: 0.253 Revision Date: 12-20-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets