Belden

1829R - Broadband Coax, Series 6, 18 AWG Solid BCCS, Foil + 60% AL Braid, PVC Jkt, CMP

(No reviews yet) Write a Review
SKU:
1829R
Shipping:
Calculated at Checkout
$0.00

Description

Broadband Coax, Series 6, 18 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, Foil + 60% Aluminum Braid Shield, PVC Jacket, CMR

Specifications

Specifications

Product Overview

Suitable ApplicationsBroadband, Cable Television (CATV), RF drop cable, Direct Broadcast Satellite (DBS), Over-The-Air (OTA) antennas

Construction Details

Series Type6

Conductor

Number of ElementSizeStrandingNom. DiameterMaterial
118 AWGSolid0.04 inBCCS - Bare Copper Covered Steel

Insulation

MaterialNom. Insulation DiameterColor Code
PE - Polyethylene (Foam)0.18 in (4.6 mm)White
Table NotesGas Injected

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duofoil®100%
2BraidAluminum60%

Outer Jacket

MaterialNom. Diameter
PVC - Polyvinyl Chloride0.275 in (6.99 mm)
Overall Cable Diameter (Nominal)0.275 in (6.99 mm)

Electrical Characteristics

Return Loss

FrequencyMin. Structural Return Loss
950 - 2250 MHz15 dB
2250 - 3000 MHz10 dB

Attenuation

FrequencyNom. AttenuationMax. Attenuation
5 MHz0.5 dB/100ft0.58 dB/100ft
55 MHz1.4 dB/100ft1.6 dB/100ft
211 MHz2.6 dB/100ft3.05 dB/100ft
500 MHz4.1 dB/100ft4.66 dB/100ft
750 MHz5.1 dB/100ft5.65 dB/100ft
862 MHz5.5 dB/100ft6.1 dB/100ft
1000 MHz6 dB/100ft6.55 dB/100ft
1450 MHz7.8 dB/100ft8 dB/100ft
1800 MHz8.6 dB/100ft8.8 dB/100ft
2250 MHz9.8 dB/100ft10 dB/100ft
3000 MHz11.3 dB/100ft11.9 dB/100ft

Electricals

Nom. Conductor DCRNom. Outer Shield DCRNom. Capacitance Cond-to-ShieldNom. Characteristic ImpedanceNom. Velocity of Prop.
28 Ohm/1000ft (92 Ohm/km)9 Ohm/1000ft (30 Ohm/km)16.2 pF/ft (53.1 pF/m)75 Ohm83%

Voltage

UL Voltage Rating
300 V RMS

Mechanical Characteristics

Temperature

UL TemperatureOperatingInstallation
75°C-40°C To +80°C-30°C To +80°C

Bend Radius

Stationary Min.Installation Min.
2 in (51 mm)2 in (51 mm)
Max. Pull Tension126 lbs (57.2 kg)
Bulk Cable Weight30 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor - Riser, Indoor
Flammability / Reaction to FireUL1666 Vertical Shaft, FT4
NEC / UL ComplianceArticle 800, CATVR, CMR
CEC / C(UL) ComplianceCMG
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Non-Plenum Number1829A

Product Notes

Notes(1)RG Type :-In Stibo it was 6 But in BPCS only Series 6 is there. (2)# Elements@Conductor1:-In Stibo it was Blank and now changed to 1. (3)Size@Conductor1 :-In Stibo it was 18 now changed to 18AWG (4)Color@Color Chart1 01 :- In stibo it was Blank now Changed to White (5)Material@OuterShield1 1 - In stibo it is Tri-Laminate (Alum+Poly+Alum) But in BPCS (Heat fusible+ Alum+ Poly+Alum) (6)Coverage@OuterShield1 2 - in stibo it was 60% Now changed to 57% (7)Cable Diameter (Nominal)- In Stibo it was Blank Now Changed to 57% (8)Bulk Cable Weight - In stibo it was 29 lbs/1000 ft Now chnaged to 30 lbs/1000 ft

History

Update and RevisionRevision Number: 0.468 Revision Date: 05-03-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 1829R 010U1000:
1829R 010U1000|Black|UnReel|1,000 ft|612825124153
Variant_Options 1829R 008U1000:
1829R 008U1000|Gray|UnReel|1,000 ft|612825124139
Variant_Options 1829R 009U1000:
1829R 009U1000|White|UnReel|1,000 ft|612825124146
View AllClose