Belden

183079A - Profibus, 1 Pr #22 Sol BC, PE Ins, OS+TC Brd, PVC jkt, CCA, PVC Jkt, PLTC CMG Profibus DP

(No reviews yet) Write a Review
SKU:
183079A
Shipping:
Calculated at Checkout
$0.00

Description

Profibus, 1 Pair 22AWG (Solid) Bare Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, PVC Inner Jacket, Continuously Corrugated Aluminum Armor, PVC Outer Jacket, PLTC CMG SUN RES Profibus DP

Specifications

Specifications

Product Overview

Suitable Applicationsexposure to rodent, crush, or cut through force, harsh environment, outdoors, data transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, humidity/moisture, dust, and oil.

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Pair(s)122 AWGSolidBC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor CodeNotes
Pair(s)PE - Polyethylene (Foam)0.035 in (0.89 mm)0.099 in (2.5 mm)Red & GreenFlame Retardant, Foam w/ skin

Outer Shield

Shield TypeMaterialCoverage
TapeBi-Laminate (Alum+Poly)100%
BraidTinned Copper (TC)65%

Inner Jacket

MaterialNom. ThicknessNom. Diameter
PVC - Polyvinyl Chloride0.043 in (1.1 mm)0.315 in (8.00 mm)

Armor

Armor Type & Material
CCAA - Continuously Corrugated Aluminum Armor

Outer Jacket

MaterialNom. ThicknessNom. Diameter
PVC - Polyvinyl Chloride0.055 in (1.4 mm)0.665 in (16.9 mm)
Overall Cable Diameter (Nominal)0.665 in (16.9 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Pair(s)16 Ohm/1000ft (52 Ohm/km)150 Ohm78%2.3 Amps per Conductor
Nom. Outer Shield DCR3.9 Ohm/1000ft (13 Ohm/km)

High Frequency (Nominal/Typical)

ElementFrequency [MHz]Nom. Insertion Loss (Attenuation)
Pair(s)0.20.27 dB/100ft
40.67 dB/100ft
161.37 dB/100ft

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)
0.21.1 dB/100m
42.65 dB/100m
165.4 dB/100m

Voltage

UL Voltage Rating
300 V (CMG, PLTC)

Mechanical Characteristics

Temperature

UL TemperatureOperating
60°C-30°C to +60°C

Bend Radius

Stationary Min.Installation Min.
2.5 in (64 mm)2.5 in
Max. Pull Tension50 lbs (23 kg)
Bulk Cable Weight170 lbs/1000ft (250 kg/km)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance
Flammability / Reaction to FireUL1685 FT4 Loading, 1202, IEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 725, Article 800, CMG, PLTC
CEC / C(UL) ComplianceCMG
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.251 Revision Date: 05-05-2023