Blue Hose® for Data Highway Plus, 1 Pair 20AWG (7x28) Tinned Copper, PE Insulation Blue & Clear, Overall Beldfoil®+Tinned Copper Braid(55%) Shield, PVC Inner Jacket, CCA Interlock Armor, Blue PVC Outer Jacket, PLTC
Specifications
Specifications
Product Overview
Suitable Applications | exposure to rodent, crush, or cut through force, harsh environment, Allen Bradley Data Highway communication interface between PLC processors, I/O devices, operator interfaces, computers and other intelligent devices, PLC processor interlocking, peer-to-peer messaging, remote programming, troubleshooting, I/O updates, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 1 | 20 AWG | 7x28 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Color Code | Notes |
---|
Pair(s) | PE - Polyethylene | 0.019 in (0.48 mm) | Clear & Blue | Twinax with rod fillers |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC |
Braid | Tinned Copper (TC) | 55% | |
Inner Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.238 in (6.05 mm) |
Armor
Armor Type & Material |
---|
CCAA - Continuously Corrugated Aluminum Armor |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.050 in (1.3 mm) | 0.515 in (13.1 mm) |
Overall Cable Diameter (Nominal) | 0.515 in (13.1 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Shield | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
---|
Pair(s) | 9.5 Ohm/1000ft (31 Ohm/km) | 19.7 pF/ft (64.6 pF/m) | 37 pF/ft | 36 pF/ft | 78 Ohm | 66% |
Nom. Outer Shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|
Pair(s) | 1 | 0.6 dB/100ft |
| 10 | 2.1 dB/100ft |
| 50 | 5 dB/100ft |
| 100 | 7.5 dB/100ft |
| 200 | 11 dB/100ft |
| 400 | 16 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (PLTC) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
60°C | -20°C to +60°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
6 in (150 mm) | 6 in |
Max. Pull Tension | 205 lbs (93.0 kg) |
---|
Bulk Cable Weight | 121 lbs/1000ft (180 kg/km) |
---|
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
---|
Flammability / Reaction to Fire | UL1685 UL Loading |
---|
NEC / UL Compliance | Article 725, PLTC |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
Other Standard Compliance(s) | Allen Bradley Part No. 1770-CD |
---|
History
Update and Revision | Revision Number: 0.241 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins